11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 6
11.2 Regenerative options
CAUTION
Do not use servo amplifiers with regenerative options other than the combinations
specified below.
Otherwise, it may cause a fire.
11.2.1 Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
(1) 200 V class
Servo
amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-RB032
[40
Ω
]
MR-RB12
[40
Ω
]
MR-RB30
[13
Ω
]
MR-RB3N
[9
Ω
]
MR-RB31
[6.7
Ω
]
MR-RB32
[40
Ω
]
(Note 1)
MR-RB50
[13
Ω
]
(Note 1)
MR-RB5N
[9
Ω
]
(Note 1)
MR-RB51
[6.7
Ω
]
MR-J4-10TM
30
MR-J4-20TM
10
30
100
MR-J4-40TM
10
30
100
MR-J4-60TM
10
30
100
MR-J4-70TM
20 30 100 300
MR-J4-100TM
20 30 100 300
MR-J4-200TM
100 300 500
MR-J4-350TM
100
300
500
MR-J4-500TM
130
300
500
MR-J4-700TM
170
300
500
Servo
amplifier
(Note 2) Regenerative power [W]
External regenerative
resistor (accessory)
MR-RB5R
[3.2
Ω
]
MR-RB9F
[3
Ω
]
MR-RB9T
[2.5
Ω
]
MR-J4-11KTM 500
(800)
500
(800)
MR-J4-15KTM 850
(1300)
850
(1300)
MR-J4-22KTM 850
(1300)
850
(1300)
Note 1. Always install a cooling fan.
2. Values in parentheses assume the installation of a cooling fan.
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...