17.2.5 Connection example with other devices
The following connection diagram shows an operation of the safety observation function using input devices
assigned to pins of the CN10A and CN10B connectors with a safety controller. By diagnosis of input signals,
the servo amplifier complies with the safety level Category 4, PL e, and SIL 3.
A1
(24V)
A2
(0V)
24 V
0 V
FLEXB
US+
FLEXB
US+
24 V
0 V
X1
X2
A1
(24V)
Q1
Q2
Q3
A2
(0V)
WS
0-CP
U0
WS
0-X
T
IO
Application
Application
CN10A
CN10B
S1
CN10A
CN10B
DO24VA
DO24VB
DO_A
DO_B
DICOMA
DI_A
DICOMB
DI_B
Safety observation function
Control circuit
Network
module
Deceleration
command
Servo
motor
Controller
KM1: Magnetic contactor
S1: Safety switch
MR-D30
MR-J4-_TM_
KM1
QX_
COM
I1
I2
I3
I4
Safety controller MELSEC-WS series
CPU module WSO-CPU0
Safety I/O combined module WS0-XTIO