11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 82
(c) Cable clamp fitting AERSBAN-_SET
Generally, connecting the grounding of the shielded wire to the SD terminal of the connector
provides a sufficient effect. However, the effect can be increased when the shielded wire is
connected directly to the grounding plate as shown below.
Install the grounding plate near the servo amplifier for the encoder cable. Peel part of the cable
sheath to expose the external conductor, and press that part against the grounding plate with the
cable clamp. If the cable is thin, clamp several cables in a bunch.
The cable clamp comes as a set with the grounding plate.
[Unit: mm]
Cable clamp
(A, B)
Cable
Earth plate
External conductor
Clamp section diagram
40
Strip the cable sheath of
the clamped area.
cutter
cable
Dimensions
[Unit: mm]
Earth plate
(Note) M4 screw
11
3
6
C
A
6
22
17.5
35
35
7
24
0 -0.
2
B ± 0.3
2-
φ
5 hole
installation hole
[Unit: mm]
Clamp section diagram
L or less
10
30
24
+ 0.
3
0
Note. Screw hole for grounding. Connect it to the grounding plate of the cabinet.
Model A
B
C
Accessory
fittings Clamp
fitting L
AERSBAN-DSET
100
86
30
Clamp A: 2pcs.
A
70
AERSBAN-ESET
70
56
Clamp B: 1pc.
B
45
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...