15. USING A DIRECT DRIVE MOTOR
15 - 2
15.1.2 Servo system with auxiliary equipment
CAUTION
Connecting a direct drive motor for different axis to the U, V, W, or CN2 may
cause a malfunction.
POINT
Equipment other than the servo amplifier and direct drive motor are optional or
recommended products.
When using the direct drive motor, set [Pr. PA01] to "_ _ 6 _".
The configuration diagram is an example of MR-J4-20TM. When using the other servo amplifiers, the
configuration will be the same as rotary servo motors except for connections of direct drive motors. Refer to
section 1.8 depending on servo amplifiers you use.
CN4
CN5
(Note 7)
MR Configurator2
CN8
CN2
CN3
(Note 4)
Battery unit
(Note 6)
Absolute position
storage unit
MR-BTAS01
Direct drive
motor
P+
C
L11
L21
P3
P4
W
V
U
L1
L2
L3
(Note 1)
R S T
D (Note 5)
Line noise
filter
(FR-BSF01)
Regenerative
option
(Note 3)
Magnetic
contactor
(MC)
Power factor
improving DC
reactor
(FR-HEL)
Molded-case
circuit breaker
(MCCB)
(Note 2)
Power
supply
Personal
computer
Network module dependence (Note 8)
Junction
terminal
block
To safety relay or
MR-J3-D05 safety
logic unit