5. PARAMETERS
5 - 18
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT EIP
PA06
*CMX
Electronic
gear
numerator
Set an electronic gear numerator.
Set the electronic gear within the following range. Setting out of the range will trigger
[AL. 37 Parameter error].
In the cyclic synchronous mode, setting anything other than 1/1 will trigger [AL. 37
Parameter error].
1
865
<
CMX
CDV
< 271471
Always set the electronic gear with servo-off state to prevent unexpected operation
due to improper setting.
This parameter corresponds to "Motor revolutions (Index: 6091h, Sub: 1)". When this
parameter is mapped for the PDO communication, the value written with MR
Configurator2 is overwritten with the controller. Thus, do not write a value with MR
Configurator2.
Setting range: 1 to 16777215
1
Set an electronic gear numerator.
Set the electronic gear within the following range. Setting out of the range will trigger
[AL. 37 Parameter error].
1
865
<
CMX
CDV
< 271471
Always set the electronic gear with servo-off state to prevent unexpected operation
due to improper setting.
This parameter corresponds to "Motor revolutions (Class ID: 64h, Ins ID: 6091h, Attr
ID: 1)". When this parameter is mapped for the I/O communication, the value written
with MR Configurator2 is overwritten with the controller. Thus, do not write a value
with MR Configurator2.
Setting range: 1 to 16777215
1
PA07
*CDV
Electronic
gear
denominator
Set an electronic gear denominator.
Set the electronic gear within the range of [Pr. PA06].
This parameter corresponds to "Shaft revolutions (Index: 6091h, Sub: 2)". When this
parameter is mapped for the PDO communication, the value written with MR
Configurator2 is overwritten with the controller. Thus, do not write a value with MR
Configurator2.
Setting range: 1 to 16777215
1
Set an electronic gear denominator.
Set the electronic gear within the range of [Pr. PA06].
This parameter corresponds to "Shaft revolutions (Class ID: 64h, Ins ID: 6091h, Attr
ID: 2)". When this parameter is mapped for the I/O communication, the value written
with MR Configurator2 is overwritten with the controller. Thus, do not write a value
with MR Configurator2.
Setting range: 1 to 16777215
1
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...