5. PARAMETERS
5 - 61
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT EIP
PE44
LMCP
Lost motion
compensation
positive-side
compensation
value
selection
Set the lost motion compensation for when reverse rotation (CW) switches to
forward rotation (CCW) in increments of 0.01% assuming the rated torque as 100%.
Setting range: 0 to 30000
0
[0.01%]
PE45
LMCN
Lost motion
compensation
negative-side
compensation
value
selection
Set the lost motion compensation for when forward rotation (CCW) switches to
reverse rotation (CW) in increments of 0.01% assuming the rated torque as 100%.
Setting range: 0 to 30000
0
[0.01%]
PE46
LMFLT
Lost motion
filter setting
Set the time constant of the lost motion compensation filter in increments of 0.1 ms.
If the time constant is "0", the torque is compensated with the value set in [Pr. PE44]
and [Pr. PE45]. If the time constant is other than "0", the torque is compensated with
the high-pass filter output value of the set time constant, and the lost motion
compensation will continue.
Setting range: 0 to 30000
0
[0.1ms]
PE47
TOF
Torque offset
Set this when canceling unbalanced torque of vertical axis. Set this assuming the
rated torque of the servo motor as 100%. The torque offset does not need to be set
for a machine not generating unbalanced torque.
The torque offset cannot be used for linear servo motors and direct drive motors. Set
0.00%.
The torque offset set with this parameter will be enabled in the position mode,
velocity mode, and torque mode. Input commands assuming torque offset for the
torque mode.
Setting range: -10000 to 10000
0
[0.01%]
PE48
*LMOP
Lost motion
compensation
function
selection
_ _ _ x Lost motion compensation selection
0: Disabled
1: Enabled
0h
_ _ x _ Unit setting of lost motion compensation non-sensitive band
0: 1 pulse unit
1: 1 kpulse unit
0h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
PE49
LMCD
Lost motion
compensation
timing
Set the lost motion compensation timing in increments of 0.1 ms.
You can delay the timing to perform the lost motion compensation for the set time.
Setting range: 0 to 30000
0
[0.1ms]
PE50
LMCT
Lost motion
compensation
non-sensitive
band
Set the lost motion compensation non-sensitive band. When the fluctuation of the
droop pulse is the setting value or less, the speed will be 0. Setting can be changed
in [Pr. PE48]. Set the parameter per encoder unit.
Setting range: 0 to 65535
0
[pulse]/
[kpulse]
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...