6. NORMAL GAIN ADJUSTMENT
6 - 5
6.2.2 Display transition and operation procedure of one-touch tuning
(1) Response mode selection
Select a response mode from 3 modes in the one-touch tuning window of MR Configurator2.
Response mode
Explanation
High mode
This mode is for high rigid system. (Note)
Basic mode
This mode is for standard system.
Low mode
This mode is for low rigid system.
Note. If the communication cycle of the controller is 2 ms or more, the gain may be
adjusted higher. In this case, readjust the gain in the basic mode or the low mode.
Refer to the following table for selecting a response mode.
Response
mode
Response
Machine characteristic
Low mode
Basic mode
High mode
Guideline of corresponding machine
Low response
General machine tool
Conveyor
Arm robot
Precision working
machine
Inserter
Mounter
Bonder
High
response
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...