4. STARTUP
4 - 15
(b) Positioning operation
Positioning operation can be performed without using the controller. Use this operation with the
forced stop reset. This operation may be used independently of whether the servo is on or off and
whether the controller is connected or not.
Exercise control on the positioning operation screen of MR Configurator2.
1) Operation pattern
Item
initial value
Setting range
Travel distance [pulse]
4000
0 to 99999999
Motor speed [r/min]
200
0 to max. speed
Acceleration/deceleration
time constant [ms]
1000
0 to 50000
Repeat pattern
Fwd. rot. (CCW) to
rev. rot. (CW)
Fwd. rot. (CCW) to rev. rot. (CW)
Fwd. rot. (CCW) to fwd. rot. (CCW)
Rev. rot. (CW) to fwd. rot. (CCW)
Rev. rot. (CW) to rev. rot. (CW)
Dwell time [s]
2.0
0.1 to 50.0
Number of repeats [time]
1
1 to 9999
2) Operation method
Operation Screen
control
Forward rotation start
Click "Forward".
Reverse rotation start
Click "Reverse".
Pause Click
"Pause".
Stop Click
"Stop".
Forced stop
Click "Forced stop".
(c) Program operation
Positioning operation can be performed in two or more operation patterns combined, without using
the controller. Use this operation with the forced stop reset. This operation may be used
independently of whether the servo is on or off and whether the controller is connected or not.
Exercise control on the program operation screen of MR Configurator2. For full information, refer to
the MR Configurator2 Installation Guide.
Operation Screen
control
Start Click
"Start".
Pause Click
"Pause".
Stop Click
"Stop".
Forced stop
Click "Forced stop".
(d) Output signal (DO) forced output
Output signals can be switched on/off forcibly independently of the servo status. Use this function for
output signal wiring check, etc. Exercise control on the DO forced output screen of MR
Configurator2.
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...