8. TROUBLESHOOTING
8 - 7
8.3 Warning list
No.
Name
Detail
No.
Detail name
Stop
method
(Note 2,
3)
Warning
Home position return
incomplete warning
90.1
Home position return incomplete
90
90.2
Home position return abnormal termination
90.5
Z-phase
unpassed
91
Servo amplifier overheat
warning (Note 1)
91.1
Main circuit device overheat warning
92
Battery cable
disconnection warning
92.1
Encoder battery cable disconnection warning
92.3
Battery
degradation
95 STO
warning
95.1
STO1 off detection
DB
95.2
STO2 off detection
DB
96
Home position setting
warning
96.1 In-position
warning
at home positioning
96.2
Command input warning at home positioning
96.4
Magnetic pole detection incomplete warning at
home positioning
98
Software limit warning
98.1
Forward rotation-side software limit reached
98.2
Reverse rotation-side software limit reached
99
Stroke limit warning
99.1
Forward rotation stroke end off
99.2
Reverse rotation stroke end off
9B.1
Excess droop pulse 1 warning
9B
Error excessive warning
9B.3
Excess droop pulse 2 warning
9B.4
Error excessive warning during 0 torque limit
9F Battery
warning
9F.1 Low
battery
9F.2
Battery degradation warning
E0
Excessive regeneration
warning (Note 1)
E0.1
Excessive regeneration warning
E1.1
Thermal overload warning 1 during operation
E1.2
Thermal overload warning 2 during operation
Overload warning 1
(Note 1)
E1.3
Thermal overload warning 3 during operation
E1
E1.4
Thermal overload warning 4 during operation
E1.5
Thermal overload warning 1 during a stop
E1.6
Thermal overload warning 2 during a stop
E1.7
Thermal overload warning 3 during a stop
E1.8
Thermal overload warning 4 during a stop
E2
Servo motor overheat
warning (Note 1)
E2.1
Servo motor temperature warning
E3
Absolute position counter
warning
E3.1
Multi-revolution counter travel distance excess
warning
E3.2
Absolute position counter warning
E3.4
Absolute positioning counter EEP-ROM writing
frequency warning
E3.5
Encoder absolute positioning counter warning
E4
Parameter warning
E4.1
Parameter setting range error warning
E6
Servo forced stop warning
E6.1
Forced stop warning
SD
E8
Cooling fan speed
reduction warning
E8.1
Decreased cooling fan speed warning
E8.2
Cooling fan stop
E9.1
Servo-on signal on during main circuit off
DB
E9
Main circuit off warning
E9.2
Bus voltage drop during low speed operation
DB
E9.3
Ready-on signal on during main circuit off
DB
EC
Overload warning 2
(Note 1)
EC.1 Overload warning 2
ED Output watt excess warning ED.1 Output watt excess warning
F0
Tough drive warning
F0.1
Instantaneous power failure tough drive warning
F0.3
Vibration tough drive warning
F2
Drive recorder - Miswriting
warning
F2.1
Drive recorder - Area writing time-out warning
F2.2
Drive recorder - Data miswriting warning
F3
Oscillation detection
warning
F3.1
Oscillation detection warning
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...