14. USING A LINEAR SERVO MOTOR
14 - 13
(c) State transition of the servo amplifier display (3-digit, 7-segment LED) at the magnetic pole detection
When the magnetic pole detection with MR Configurator2 is normally executed, the servo amplifier
display (3-digit, 7-segment LED) shows the state as below.
The decimal point
flickers.
Servo-off status
During the
magnetic pole
detection
Magnetic pole
detection
completion
(servo-on status)
(2) Preparation for the magnetic pole detection
POINT
When you select the test operation mode with the test operation select switch
(SW1-1), the network communication for the servo amplifier and later will be
blocked.
For the magnetic pole detection, use the test operation mode (positioning operation) of MR
Configurator2. Turn off the servo amplifier power, and set the test operation select switch (SW1-1) as
shown below. Turning on the power enables the test operation mode.
1
ON
2
Set SW1-1 to "ON (up)".
1
ON