3. SIGNALS AND WIRING
3 - 24
3.5 Signal (device) explanations
For the I/O interfaces (symbols in I/O division column in the table), refer to section 3.8.2.
The pin numbers in the connector pin No. column are those in the initial status.
3.5.1 Input device
(1) Input device pin
The following shows the input device pins and parameters for setting devices.
Connector pin No.
Parameter
Initial device
I/O division
CN3-2 [Pr.
PD03] LSP
DI-1
CN3-12 [Pr.
PD04] LSN
CN3-19 [Pr.
PD05] DOG
CN3-10 [Pr.
PD38] TPR1
CN3-20 [Pr.
PA04] EM2
(2) Input device explanations
Device Symbol
Connector
pin No.
Function and application
I/O
division
Forced stop 2
EM2
CN3-20 Turn off EM2 (open between commons) to decelerate the servo motor to a stop
with commands.
Turn EM2 on (short between commons) in the forced stop state to reset that
state.
Set [Pr. PA04] to "2 1 _ _" to disable EM2.
The following shows the setting of [Pr. PA04].
DI-1
[Pr. PA04]
setting
EM2/EM1
Deceleration method
EM2 or EM1 is off
Alarm occurred
0 0 _ _
EM1
MBR (Electromagnetic
brake interlock) turns off
without the forced stop
deceleration.
MBR (Electromagnetic
brake interlock) turns off
without the forced stop
deceleration.
2 0 _ _
EM2
MBR (Electromagnetic
brake interlock) turns off
after the forced stop
deceleration.
MBR (Electromagnetic
brake interlock) turns off
after the forced stop
deceleration.
0 1 _ _
Not using
EM2 or
EM1
MBR (Electromagnetic
brake interlock) turns off
without the forced stop
deceleration.
2 1 _ _
Not using
EM2 or
EM1
MBR (Electromagnetic
brake interlock) turns off
after the forced stop
deceleration.
EM2 and EM1 are mutually exclusive.
EM2 has the same function as EM1 in the torque mode.
Forced stop 1
EM1
(CN3-20) When using EM1, set [Pr. PA04] to "0 0 _ _" to enable EM1.
Turn EM1 off (open between commons) to bring the servo motor to a forced
stop state. The base circuit shuts off, and the dynamic brake is operated and
decelerates the servo motor to a stop.
Turn EM1 on (short between commons) in the forced stop state to reset that
state.
Set [Pr. PA04] to "0 1 _ _" to disable EM1.
DI-1
Touch probe 1
TPR1
CN3-10 The touch probe function is available to latch the current position by sensor
input. Turn it on to latch the current position. For the touch probe function, refer
to the MR-J4-_TM_ Servo Amplifier Instruction Manual for each communication
method.
DI-1
Touch probe 2
TPR2
CN3-1
DI-1
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...