5. PARAMETERS
5 - 20
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT EIP
PA09
RSP
Auto tuning
response
Set the auto tuning response.
16
Setting
value
Machine characteristic
Setting
value
Machine characteristic
Response
Guideline for
machine
resonance
frequency [Hz]
Response
Guideline for
machine
resonance
frequency [Hz]
1
Low
response
Middle
response
2.7
21
Middle
response
High
response
67.1
2
3.6
22
75.6
3
4.9
23
85.2
4
6.6
24
95.9
5
10.0
25
108.0
6
11.3
26
121.7
7
12.7
27
137.1
8
14.3
28
154.4
9
16.1
29
173.9
10
18.1
30
195.9
11
20.4
31
220.6
12
23.0
32
248.5
13
25.9
33
279.9
14
29.2
34
315.3
15
32.9
35
355.1
16
37.0
36
400.0
17
41.7
37
446.6
18
47.0
38
501.2
19
52.9
39
571.5
20
59.6
40
642.7
Setting range: 1 to 40
PA10
INP
In-position
range
Set an in-position range per command pulse.
To change it to the servo motor encoder pulse unit, set [Pr. PC06].
When [Pr. PC06] is set to "_ _ _ 0" in the profile mode, the unit can be changed 10-3
[degree] or [pulse] with the setting of [Pr. PT01].
Setting range: 0 to 65535
1600
Refer
to
Function
column
for unit.
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...