4. STARTUP
4 - 17
4.5.2 Motor-less operation in controller
POINT
Connect the controller to the servo amplifier before the motor-less operation.
The motor-less operation cannot be used in the fully closed loop control mode,
linear servo motor control mode, or DD motor control mode.
(1) Motor-less operation
Without connecting the servo motor to the servo amplifier, output signals or status displays can be
provided in response to the controller commands as if the servo motor is actually running. This operation
may be used to check the controller sequence. Use this operation with the forced stop reset. Use this
operation with the servo amplifier connected to the controller.
To stop the motor-less operation, set "Disabled (_ _ _ 0)" of "Motor-less operation selection" in [Pr.
PC05]. The motor-less operation will be disabled from the next power-on.
(a) Load conditions
Load item
Condition
Load torque
0
Load to motor inertia ratio
[Pr. PB06 Load to motor inertia ratio/load to motor mass
ratio]
(b) Alarms
The following alarms and warning do not occur. However, the other alarms and warnings occur as
when the servo motor is connected.
[AL. 16 Encoder initial communication error 1]
[AL. 1E Encoder initial communication error 2]
[AL. 1F Encoder initial communication error 3]
[AL. 20 Encoder normal communication error 1]
[AL. 21 Encoder normal communication error 2]
[AL. 25 Absolute position erased]
[AL. 92 Battery cable disconnection warning]
[AL. 9F Battery warning]
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...