11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 21
Brake unit
Resistor unit
Number of
connected
units
Permissible
continuous
power [kW]
Resultant
resistance [
Ω
]
Applicable servo
amplifier (Note 3)
400 V
class
FR-BU2-H30K FR-BR-H30K
1
1.99
16 MR-J4-500TM4
MR-J4-700TM4
MR-J4-11KTM4
(Note 2)
FR-BU2-H55K FR-BR-H55K
1
3.91
8
MR-J4-11KTM4
MR-J4-15KTM4
MR-J4-22KTM4
FR-BU2-H75K MT-BR5-H75K
1
7.5
6.5 MR-J4-22KTM4
Note 1. Only when using servo motor HG-RR353/HG-UR352
2. When HG-JR11K1M4 servo motor is used, limit the torque during power running to 180% or less, or the servo
motor speed to 1800 r/min or less.
3. When the brake unit is selected by using the capacity selection software, a brake unit other than the combinations
listed may be shown. Refer to the combinations displayed on the capacity selection software for detailed
combinations.
11.3.2 Brake unit parameter setting
Whether a parameter can be changed or not is listed below.
Parameter Change
possible/
impossible
Remark
No. Name
0
Brake mode switchover
Impossible
Do not change the parameter.
1
Monitor display data selection
Possible
Refer to the FR-BU2 Instruction Manual.
2
Input terminal function selection 1
Impossible
Do not change the parameter.
3
Input terminal function selection 2
77
Parameter write selection
78
Cumulative energization time
carrying-over times
CLr Parameter
clear
ECL
Alarm history clear
C1
For manufacturer setting
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...