APPENDIX
App. - 21
d
a
c
b
c
d1
a1
e
Servo amplifier
Variable dimensions [mm]
Screw
size
a a1 b
c
D
d1 e
MR-J4-10TM(1)/MR-J4-20TM(1)/
MR-J4-40TM(1)/MR-J4-60TM
6
6
156 ± 0.5
6
M5
MR-J4-70TM/MR-J4-100TM
12
12
156 ± 0.5
6
42 ± 0.3
M5
MR-J4-200TM(4)/MR-J4-350TM
6
45
156 ± 0.5
6
78 ± 0.3
M5
MR-J4-500TM
6
6
235 ± 0.5
7.5
93 ± 0.5
93 ± 0.5
M5
MR-J4-700TM
6
6
285 ± 0.5
7.5
160 ± 0.5
160 ± 0.5
M5
MR-J4-11KTM(4)/MR-J4-15KTM(4)
12
12
380 ± 0.5
10
196 ± 0.5
196 ± 0.5
M5
MR-J4-22KTM(4)
12
12
376 ± 0.5
12
236 ± 0.5
236 ± 0.5
M10
MR-J4-60TM4/MR-J4-100TM4
12
12
156 ± 0.5
6
42 ± 0.3
M5
MR-J4-350TM4
6
6
235 ± 0.5
7.5
93 ± 0.5
93 ± 0.5
M5
MR-J4-500TM4
6
6
235 ± 0.5
7.5
118 ± 0.5
118 ± 0.5
M5
MR-J4-700TM4
6
6
285 ± 0.5
7.5
160 ± 0.5
160 ± 0.5
M5
App. 4.9 Check list for user documentation
MR-J4 installation checklist for manufacturer/installer
The following items must be satisfied by the initial test operation at least. The manufacturer/installer must
be responsible for checking the standards in the items.
Maintain and keep this checklist with related documents of machines to use this for periodic inspection.
1. Is it based on directive/standard applied to the machine?
Yes [ ], No [ ]
2. Is directive/standard contained in Declaration of Conformity (DoC)?
Yes [ ], No [ ]
3. Does the protection instrument conform to the category required?
Yes [ ], No [ ]
4. Are electric shock protective measures (protective class) effective?
Yes [ ], No [ ]
5. Is the STO function checked (test of all the shut-off wiring)?
Yes [ ], No [ ]
Checking the items will not be instead of the first test operation or periodic inspection by professional
engineers.
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...