5. PARAMETERS
5 - 75
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT EIP
PT50
STB
Deceleration
time constant
Set the deceleration time taken from the rated speed to 0 r/min or 0 mm/s to the
command.
In the profile mode
Set a deceleration time constant for the position mode and velocity mode. Setting
a value exceeding 20000 ms in the position mode will trigger [AL. F4].
This parameter corresponds to "Profile deceleration (Index: 6084h)". When this
parameter is mapped for the PDO communication, the value written with MR
Configurator2 is overwritten with the controller. Thus, do not write a value with MR
Configurator2.
Setting range: 0 to 50000
0
[ms]
Set the deceleration time taken from the rated speed to 0 r/min or 0 mm/s to the
command.
In the profile mode
Set a deceleration time constant for the position mode and velocity mode. Setting
a value exceeding 20000 ms in the position mode will trigger [AL. F4].
This parameter corresponds to "Profile deceleration (Class ID: 64h, Ins ID: 6084h,
Attr ID: 0)". When this parameter is mapped for the I/O communication, the value
written with MR Configurator2 is overwritten with the controller. Thus, do not write a
value with MR Configurator2.
Setting range: 0 to 50000
0
[ms]