12. ABSOLUTE POSITION DETECTION SYSTEM
12 - 4
12.2.2 Using MR-BAT6V1BJ battery for junction battery cable
POINT
MR-BAT6V1BJ is compatible only with HG series servo motors. It cannot be
used with direct drive motors.
MR-BAT6V1BJ cannot be used for fully closed loop system and scale
measurement function.
(1) Configuration diagram
EEP-ROM memory
Servo amplifier
Current
position
LS
Detecting the
number of
revolutions
1X
Detecting the
position within
one revolution
Posi
tion contr
o
l
MR-BAT6V1BJ
Battery
Counter within one revolution
Cumulative revolution counter
(1 pulse/rev)
Servo motor
Command
position
High-speed
serial
communication
LSO
1XO
Home position data
Controller
Step-down
circuit
(6 V
→
3.4 V)
Step-down circuit
Primary lithium battery
Speed contr
o
l
Backup at
power off
(2) Specifications
(a) Specification list
Item Description
System
Electronic battery backup type
Maximum revolution range
Home position ± 32767 rev.
(Note 1)
Maximum speed at power
failure [r/min]
Rotary servo motor
6000
(only when acceleration time until 6000 r/min is 0.2 s or more)
(Note 2)
Battery backup time
Rotary servo motor
Approximately 20,000 hours
(equipment power supply: off, ambient temperature: 20
˚
C)
Approximately 29,000 hours
(power-on time ratio: 25%, ambient temperature: 20 °C) (Note 3)
Note 1. Maximum speed available when the shaft is rotated by external force at the time of power failure or the like. Also, if power is
switched on at the servo motor speed of 3000 r/min or higher, position mismatch may occur due to external force or the like.
2. The data-holding time by the battery using MR-BAT6V1BJ. Replace the batteries within three years since the operation start
regardless of the power supply of the servo amplifier on/off. If the battery is used out of specification, [AL. 25 Absolute position
erased] may occur.
3. The power-on time ratio 25% is equivalent to 8 hours power on for a weekday and off for a weekend.
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...