11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 16
When using cooling fans, install them using the mounting holes provided in the bottom of the
regenerative option.
MR-RB5R/MR-RB9F/MR-RB9T/
MR-RB5K-4/MR-RB6K-4
Mounting screw
4-M3
Top
Bottom
TE1
G4 G3 C P
TE1 terminal block
2 cooling fans
(1.0 m
3
/min or more,
92 mm × 92 mm)
11.2.5 Dimensions
(1) MR-RB12
[Unit: mm]
5
144
Approx. 20
169
168
156
6
12
6
36
40
φ
6 mounting hole
TE1
15
Approx. 6
149
2
TE1 terminal
G3
G4
P
C
Applicable wire size: 0.2 mm
2
to 2.5 mm
2
(AWG 24 to
12)
Tightening torque: 0.5 to 0.6 [N•m]
Mounting screw
Screw size: M5
Tightening torque: 3.24 [N•m]
Mass: 1.1 [kg]