13. USING STO FUNCTION
13 - 11
(b) When outputting two STO states by using one TOFB
If polarity of diode is
reversed, servo amplifier
will malfunction.
TOFCOM
Servo amplifier
TOFB2
Load
TOFB1
(Note)
24 V DC ± 10%
300 mA
Note. If the voltage drop (maximum of 5.2 V) interferes with the relay operation, apply high
voltage (maximum of 26.4 V) from external source.