4. STARTUP
4 - 14
4.5.1 Test operation mode in MR Configurator2
POINT
When the test operation mode is selected with the test operation select switch
(SW1-1), the Network communication for the servo amplifier in the test operation
mode and the following servo amplifiers is blocked.
For the EtherCAT, turning on the test operation select switch (SW1-1) with the
following parameter settings triggers [AL. 37 Parameter error].
"Automatic selection by each network (_ _ _ 0) (initial value)" of "Control mode
selection" is selected in [Pr. PA01].
"Switching by fully closed loop selection command from controller (C_CLD)
and Input device CLD (Fully closed loop selection) (_ _ _ 1)" of "Fully closed
loop function selection" is selected in [Pr. PE01].
In this case, select "Cyclic synchronous mode (_ _ _ 1)" of "Control mode
selection" in [Pr. PA01], and turn on the test operation select switch (SW1-1).
(1) Test operation mode
(a) Jog operation
Jog operation can be performed without using the controller. Use this operation with the forced stop
reset. This operation may be used independently of whether the servo is on or off and whether the
controller is connected or not.
Exercise control on the jog operation screen of MR Configurator2.
1) Operation pattern
Item
initial value
Setting range
Motor speed [r/min]
200
0 to max. speed
Acceleration/deceleration
time constant [ms]
1000
0 to 50000
2) Operation method
a) When the check box of "Rotation only while the CCW or CW button is being pushed." is
checked.
Operation Screen
control
Forward rotation start
Keep pressing "Forward".
Reverse rotation start
Keep pressing "Reverse".
Stop
Release "Forward" or "Reverse".
Forced stop
Click "Forced stop".
b) When the check box of "Rotation only while the CCW or CW button is being pushed." is not
checked.
Operation Screen
control
Forward rotation start
Click "Forward".
Reverse rotation start
Click "Reverse".
Stop Click
"Stop".
Forced stop
Click "Forced stop".
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...