5. PARAMETERS
5 - 43
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Network
ECT EIP
PC09
MOD1
Analog
monitor 1
output
_ _ x x Analog monitor 1 output selection
Select a signal to output to MO1 (Analog monitor 1). Refer to app. 8 (3) for detection
point of output selection.
Refer to table 5.8 for settings.
00h
_ x _ _ For manufacturer setting
0h
x _ _ _
0h
Table 5.8 Analog monitor setting value
Setting
value
Item
Operation
mode (Note 1)
Standard
F
ull.
Lin.
DD
_ _ 0 0 Servo motor speed
(±8 V/max. speed)
_ _ 0 1 Torque or thrust
(±8 V/max. torque or max. thrust) (Note 3)
_ _ 0 2 Servo motor speed
(+8 V/max. speed)
_ _ 0 3 Torque or thrust
(+8 V/max. torque or max. thrust) (Note 3)
_ _ 0 4 Current command (±8 V/max. current command)
_ _ 0 5 Speed command (±8 V/max. speed)
_ _ 0 6 Servo motor-side droop pulses (±10 V/100 pulses)
(Note 2)
_ _ 0 7 Servo motor-side droop pulses (±10 V/1000 pulses)
(Note 2)
_ _ 0 8 Servo motor-side droop pulses (±10 V/10000 pulses)
(Note 2)
_ _ 0 9 Servo motor-side droop pulses (±10 V/100000 pulses)
(Note 2)
_ _ 0 D Bus voltage (200 V class and 100 V class: +8 V/400 V,
400 V class: +8 V/800 V)
_ _ 0 E Speed command 2 (±8 V/max. speed)
_ _ 1 0 Load-side droop pulses (±10 V/100 pulses) (Note 2)
_ _ 1 1 Load-side droop pulses (±10 V/1000 pulses) (Note 2)
_ _ 1 2 Load-side droop pulses (±10 V/10000 pulses) (Note 2)
_ _ 1 3 Load-side droop pulses (±10 V/100000 pulses) (Note 2)
_ _ 1 4 Load-side droop pulses (±10 V/1 Mpulses) (Note 2)
_ _ 1 5 Servo motor-side/load-side position deviation
(±10 V/100000 pulses)
_ _ 1 6 Servo motor-side/load-side speed deviation
(±8 V/max. speed)
_ _ 1 7 Internal temperature of encoder (±10 V/±128
˚
C)
Note 1. Items with are available for each operation mode.
Standard: Standard (semi closed loop system) use of the rotary servo motor
Full.: Fully closed loop system use of the rotary servo motor
Lin.: Linear servo motor use
DD: Direct drive (DD) motor use
2.
Encoder pulse unit
3. The value in [Pr. PA11] or [Pr. PA12] whichever is higher is applied for the maximum
torque or maximum thrust.
Содержание MR-J4 TM Series
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 225: ...5 PARAMETERS 5 86 MEMO ...
Страница 295: ...8 TROUBLESHOOTING 8 14 MEMO ...
Страница 439: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Страница 521: ...16 FULLY CLOSED LOOP SYSTEM 16 20 MEMO ...
Страница 578: ...APPENDIX App 41 ...