Страница 2: ...Contents Intro 1 Front Panel 1 Rear Panel 2 Tube Life Biasing 5 Safety 9 Limited Lifetime Warranty 10 Care and Maintenance 1 1 Tube Bias Diagram 1 1...

Страница 3: ...ble Adds treble frequencies when turned clock wise and reduces treble when turned counter clockwise Middle Adds mid range frequencies when turned clock wise and reduces mid range when turned counter c...

Страница 4: ...re but in reverse order allowing the amp to idle in Standby mode for about 30 seconds before powering down While it is perfectly okay to turn the amp OFF immediately idling in standby before powering...

Страница 5: ...n pairs a nd if an output tube fuse blows power is cut off to one pair of the four KT88 output tubes even though only one is likely damaged This allows the amp continue to run safely on the remaining...

Страница 6: ...y are best placed in the effects loop The effects loop is located after the preamp section of the amp where most of the overdrive distorted tone is generated This allows time based effects to be be he...

Страница 7: ...depending on how hard the amp is played Sometimes they die gracefully sometimes abruptly causing a fuse to blow which in turn protects the amplifier from further damage It s sometimes possible to see...

Страница 8: ...detailed information about your amp s biasing system and bias procedure in the following sections Bias Control Test Points Every Science Amplifier comes equipped with user accessible bias test points...

Страница 9: ...ed for a sustained period the output tubes will likely fail Science Amplification is not responsible for output tube failure due to maladjustment of bias controls Please familiarize yourself with the...

Страница 10: ...t to the tubes you are measuring 5 Plug the positive probe into the red test point behind the tube you are measuring 6 Take note of the reading on the meter 7 Remove the probe from the red point and r...

Страница 11: ...inimum All the way counter clockwise 4 Follow steps 2 7 from the Measuring Adjusting Output Tube Bias instructions above 1 Turn the bias control clock wise with a small screwdriver until you reach the...

Страница 12: ...o the original owner Any unauthorized repair modification or tampering voids this warranty The warranty excludes Normal wear and tear worn out tubes jacks cosmetic damage etc Misuse and abuse operatin...

Страница 13: ...need cleaning use only a soft clean dry or damp cloth to wipe off smudges To clean tolex wipe with a damp cloth Periodically check the 4 mounting screws on the bottom to make sure they are tightened...

Страница 14: ...12...