11
12
13
14
15
16
17
18
19
20
329
13. (T) Multi-Function Input Terminal Parameters
13.6 Input terminal function selection
*1
The communication protocol affects which terminals can be used. For details, refer to the Instruction Manual (Communication) or the Instruction
Manual of each communication option.
Input signal list
• Refer to the following table and set the parameters.
Setting
Signal
name
Function
Related parameter
Refer to
page
0
RL
Pr.59
= "0" (initial value)
Low-speed operation command
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
≠
Remote setting (setting clear)
Pr.59
Pr.270
= "1, 11"
Stop-on-contact selection 0
Pr.270, Pr.275, Pr.276
1
RM
Pr.59
= "0" (initial value)
Middle-speed operation
command
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
≠
Remote setting (deceleration)
Pr.59
2
RH
Pr.59
= "0" (initial value)
High-speed operation command
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.59
≠
Remote setting (acceleration)
Pr.59
3
RT
Second function selection
Pr.44 to Pr.48, Pr.51, Pr.450
to Pr.463, Pr.569, Pr.832,
Pr.836, etc.
Pr.270
= "1, 11"
Stop-on-contact selection 1
Pr.270, Pr.275, Pr.276
4
AU
Terminal 4 input selection
Pr.267
5
JOG
Jog operation selection
Pr.15, Pr.16
7
OH
External thermal relay input
Pr.9
8
REX
15-speed selection (Combination with multi-speeds of RL, RM, and
RH)
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
10
X10
Inverter run enable (FR-XC/FR-HC2/FR-CV connection)
Pr.17, Pr.30, Pr.70
12
X12
PU operation external interlock
Pr.79
13
X13
External DC injection brake operation start
Pr.10 to Pr.12
14
X14
PID control valid
Pr.127 to Pr.134, Pr.575 to
Pr.577
15
BRI
Brake opening completion
Pr.278 to Pr.285
16
X16
PU/External operation switchover (External operation with X16-ON)
Pr.79, Pr.340
18
X18
V/F switchover (V/F control with X18-ON)
Pr.80, Pr.81, Pr.800
23
LX
Pre-excitation
Pr.850
24
MRS
Output stop
Pr.17
25
STP
(STOP)
Start self-holding selection
Pr.250
26
MC
Control mode switchover
Pr.800
27
TL
Torque limit selection
Pr.815
30
JOG2
Pr.15, Pr.16
37
X37
Traverse function selection
Pr.592 to Pr.597
42
X42
Torque bias selection 1
Pr.840 to Pr.845
43
X43
Torque bias selection 2
Pr.840 to Pr.845
46
TRG
Trace trigger input
Pr.1020 to Pr.1047
47
TRC
Trace sampling start/end
Pr.1020 to Pr.1047
50
SQ
Sequence start
Pr.414
51
X51
Fault clear
Pr.414
60
STF
Forward rotation command (assignable to the STF terminal
(Pr.178)
only)
Pr.250
61
STR
Reverse rotation command (assignable to the STR terminal
(Pr.179)
only)
Pr.250
62
RES
Inverter reset
Pr.75
65
X65
PU/NET operation switchover (PU operation with X65-ON)
Pr.79, Pr.340
66
X66
External/NET operation switchover (NET operation with X66-ON)
Pr.79, Pr.340
67
X67
Command source switchover (command by
Pr.338
or
Pr.339
enabled with X67-ON)
Pr.338, Pr.339
72
X72
PID P control switchover
Pr.127 to Pr.134, Pr.575 to
Pr.577
74
X74
Magnetic flux decay output shutoff
Pr.850
92
X92
Emergency stop
Pr.1103
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...