118
5. Speed Control
5.4 Setting the torque limit level
• When the difference between the set speed and rotation speed is -2 Hz or less, the torque limit level during deceleration
Torque limit level during deceleration (
Pr.817
) activates.
Changing the setting increments of the torque limit level (Pr.811)
• The setting increments of
Pr.22 Torque limit level, Pr.801 Output limit level
, and
Pr.812 to Pr.817 Torque limit level
can be changed to 0.01% by setting
Pr.811 Set resolution switchover
= "10".
NOTE
• The internal resolution of the torque limit is 0.024% (100/2
12
), and fractions below this resolution are rounded off.
• When Real sensorless vector control is selected, fractions below a resolution equivalent to 0.1% are rounded off even if
Pr.811
= "10" is set.
Changing the torque characteristic of the constant-power range (Pr.801,
Pr.803)
• For the torque limit operation, the torque characteristic can be changed between in the low-speed range and in the constant
power range.
Pr.811 setting
Torque limit setting increments
0 (initial value)
0.1%
10
0.01%
Acceleration
Constant speed
Deceleration
1s
Pr.816
Torque limit level
during acceleration
Torque limit set to
Pr.810
Pr.817
Torque limit level
during deceleration
Set
frequency
Output
frequency
(Hz)
Time
-2 Hz < set speed - rotation speed < 2 Hz
Torque limit
level
-2 Hz set speed - rotation speed
Pr.803 setting
Torque characteristic in low-speed range
Torque characteristic in constant-power range
Torque characteristic
Output limit
0 (initial value)
Torque rise
Constant motor output
—
1
Constant torque
Constant torque
Disabled
2
Constant torque
Constant torque
Enabled
10
Constant torque
Constant motor output
—
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...