29
2. Basic Operation
2.4 Frequently-used parameters (simple mode parameters)
1
2
3
4
5
6
7
8
9
10
2.4
Frequently-used parameters (simple mode
parameters)
Parameters that are frequently used for the FR-E800 series are grouped as simple mode parameters.
When
Pr.160 User group read selection
= "9999", only the simple mode parameters are displayed on the operation panel.
This section explains the simple mode parameters.
2.4.1
Simple mode parameter list
For simple variable-speed operation of the inverter, the initial values of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter's setting, change and check can be made
on the operation panel.
•
Pr.160 User group read selection
can narrow down the displayed parameters to only the simple mode parameters. (In the
initial setting, all parameters are displayed.) Set
Pr.160 User group read selection
as required. (To change the parameter
Pr.160 setting
Description
9999
Only simple mode parameters are displayed.
0 (initial value)
All parameters (simple mode parameters and extended parameters)
are displayed.
1
Only parameters registered in user groups are displayed.
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...