8. (E) Environment Setting Parameters
8.13 Setting multiple parameters by batch
1
2
3
4
5
6
7
8
9
10
8.13
Setting multiple parameters by batch
The setting of particular parameters is changed by batch, such as communication parameters for connection with the Mitsubishi
Electric human machine interface (GOT), the parameters for the rated frequency (50/60 Hz) setting, or the parameters for
acceleration/deceleration time increment.
Multiple parameters are changed automatically. Users do not have to consider each parameter number (automatic parameter
setting).
*1
The read value is always "9999".
Automatic parameter setting (Pr.999)
• Select which parameters to automatically set from the following table, and set them in
Pr.999
. Multiple parameter settings
are changed automatically. Refer to
for the list of parameters that are changed automatically.
NOTE
• If the automatic setting is performed with
Pr.999
or the automatic parameter setting mode, the settings including the changed
parameter settings (changed from the initial setting) will be automatically changed. Before performing the automatic setting,
confirm that changing the parameters will not cause any problem.
• "AUTO" is displayed on the operation panel also when the user group function is used (
Pr.160
= "1"). However, if
Pr.999
is
not registered in the group, the automatic setting cannot be performed (write error (Er1) occurs).
GOT initial setting (PU connector) (Pr.999 = "10, 12")
*1
The setting is changed when
Pr.414
= "0" (initial setting).
Pr.
Name
Initial value
Setting
range
Description
999
E431
Automatic parameter
setting
10
GOT initial setting (PU connector)
"Controller Type" in GOT: FREQROL
500/700/800, SENSORLESS SERVO
12
GOT initial setting (PU connector)
"Controller Type" in GOT: FREQROL
800 (Automatic Negotiation)
20
50 Hz rated frequency
21
60 Hz rated frequency
9999
No action
Pr.999
setting
Description
Operation in the automatic parameter setting mode
10
Automatically sets the communication parameters for the GOT
connection with a PU connector ("Controller Type" in GOT:
FREQROL 500/700/800, SENSORLESS SERVO)
"AUTO"
→
"GOT"
→
Write "1".
12
Automatically sets the communication parameters for the GOT
connection with a PU connector ("Controller Type" in GOT:
FREQROL 800 (Automatic Negotiation))
"AUTO"
→
"GOT"
→
Write "2".
20
50 Hz rated
frequency
Sets the related parameters of the rated
frequency according to the power supply
frequency
"AUTO"
→
"F50"
→
Write "1".
21
60 Hz rated
frequency
—
Pr.
Name
Initial value
Pr.999 = "10"
Pr.999 = "12"
Refer to page
79
Operation mode selection
0
1
1
118
PU communication speed
192
192
1152
Instruction Manual
(Communication)
119
PU communication stop bit length / data length 1
10
0
120
PU communication parity check
2
1
1
121
PU communication retry count
1
9999
9999
122
PU communication check time interval
9999
9999
9999
123
PU communication waiting time setting
9999
0 ms
0 ms
124
PU communication CR/LF selection
1
1
1
340
Communication startup mode selection
0
0
0
414
PLC function operation selection
0
—
2
549
Protocol selection
0
0
0
Instruction Manual
(Communication)
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...