9. (F) Settings for Acceleration/Deceleration
9.3 Remote setting function
Acceleration/deceleration operation
• The output frequency changes as follows when the set frequency is changed by the remote setting function.
NOTE
• If the time setting of the output frequency is longer than the time setting of the set frequency, the motor accelerates/decelerates
according to the time setting of the output frequency.
• Deceleration to the main speed or lower
By setting
Pr.59
= "11 to 13", the speed can be decelerated to the frequency lower than the main speed (set by the External
operation frequency (except multi-speed setting) or PU operation frequency).
• Regardless of whether the remote setting is enabled or disabled, the acceleration/deceleration time set for the output
frequency can be changed to the second acceleration/deceleration time by turning ON the RT signal.
• The acceleration/deceleration time setting of the set frequency is fixed at the
Pr.44
/
Pr.45
setting.
Frequency setting storage
• The remotely set frequency is stored, held, or cleared according to the
Pr.59
setting. When the inverter is turned ON again
and the operation is resumed, the setting shown in the parentheses will be applied.
• Storage conditions
The remotely-set frequency is stored at the point when the start signal (STF or STR) turns OFF. The remotely-set
frequency is stored every minute after turning OFF (ON) the RH and RM signals together. Every minute, the frequency is
overwritten in the EEPROM if the latest frequency is different from the previous one when comparing the two. This cannot
be written using the RL signal.
Frequency
Time setting
Description
Set frequency
Pr.44
/
Pr.45
The set frequency increases/decreases by remote setting according to the
Pr.44
/
Pr.45
setting.
Output frequency
Pr.7
/
Pr.8
The output frequency increases/decreases by the set frequency according to the
Pr.7
/
Pr.8
setting.
Time
Time
Pr.44
Pr.45
ON
ON
Pr.7
Pr.8
Output frequency
Set frequency
Acceleration (RH)
Deceleration (RM)
Pr.59 setting
Power OFF
STF/STR signal OFF
1, 11
Stored (stored frequency)
Held (stored frequency)
2, 12
Cleared (main speed)
Held (stored frequency)
3, 13
Clear (main speed)
Cleared (main speed)
0
ON
ON
ON
Deceleration(RM)
Acceleration(RH)
Forward rotation(STF)
Main speed
Minimum
frequency
Time
Output frequency
(Hz)
Pr.59
= “ 1, 2, 3”
Decelerates to the main speed
Pr.59
= “ 11, 12, 13”
Decelerates to the minimum frequency
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...