71
3. Parameters
3.2 Parameter list (by parameter number)
1
2
3
4
5
6
7
8
9
10
Pr.1000 to Pr.1099
Energy saving
mo
nit
o
ring
891
M023
Cumulative power monitor
digit shifted times
0 to 4, 9999
1
9999
892
M200
Load factor
30% to 150%
0.1%
100%
893
M201
Energy saving monitor
reference (motor capacity)
0.1 to 30 kW
0.01 kW
Inverter rated
capacity
894
M202
Control selection during
commercial power-supply
operation
0 to 3
1
0
895
M203
Power saving rate reference
value
0, 1, 9999
1
9999
896
M204
Power unit cost
0 to 500, 9999
0.01
9999
897
M205
Power saving monitor
average time
0 to 1000 h, 9999
1 h
9999
898
M206
Power saving cumulative
monitor clear
0, 1, 10, 9999
1
9999
899
M207
Operation time rate
(estimated value)
0% to 100%, 9999
0.1%
9999
—
986
H110
Display safety fault code
[E800-SCE]
0 to 127
1
0
PU
990
E104
PU buzzer control
0, 1
1
1
991
E105
PU contrast adjustment
0 to 63
1
58
Mo
ni
to
ri
ng
992
M104
Operation panel setting dial
push monitor selection
[E800]
0 to 3, 5 to 14, 17 to 20,
23 to 25, 32, 33, 35,
38, 40 to 42, 44, 45, 50
to 57, 61, 62, 67, 91,
97, 100
1
0
—
997
H103
Fault initiation
0 to 255, 9999
1
9999
—
998
E430
PM parameter
initialization
0, 8009, 8109, 9009,
9109,
1
0
—
999
E431
Automatic parameter
setting
10, 12, 20, 21, 9999
1
9999
Function
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial
value
*1
Refer
to page
Customer
setting
Gr.1
Gr.2
Simple
Simple
Simple
Simple
Simple
Simple
Function
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial
value
Refer
to page
Customer
setting
Gr.1
Gr.2
—
1002
C150
Lq tuning target current
adjustment coefficient
50% to 150%, 9999
0.1%
9999
Cl
o
ck
1006
E020
Clock (year)
2000 to 2099
1
2000
1007
E021
Clock (month, day)
Jan. 1 to Dec. 31
1
101
1008
E022
Clock (hour, minute)
0:00 to 23:59
1
0
—
1015
A607
Integral stop selection at
limited frequency
0 to 2
1
0
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...