14. (C) Motor Constant Parameters
14.3 Offline auto tuning for a PM motor (motor constant tuning)
14.3
Offline auto tuning for a PM motor (motor constant
tuning)
The offline auto tuning enables the optimal operation of a PM motor.
• Automatic measurement of motor constants (offline auto tuning) enables optimal operation of motors for PM sensorless
vector control even when motor constants vary or when the wiring distance is long.
For the offline auto tuning under Advanced magnetic flux vector control, Real sensorless vector control, and Vector control,
refer to
Pr.
Name
Initial
value
Setting range
Description
71
C100
Applied motor
0
0, 3, 5, 6, 10, 13, 15, 16,
20, 23, 30, 33, 40, 43, 50,
53, 70, 73, 1800, 1803,
8090, 8093, 9090, 9093
By selecting a motor, the thermal characteristic and motor
constant of each motor are set.
80
C101
Motor capacity
9999
0.1 to 30 kW
Set the applied motor capacity.
9999
V/F control
81
C102
Number of motor poles
9999
2, 4, 6, 8, 10, 12
Set the number of motor poles.
9999
V/F control
9
C103
Electronic thermal O/L
relay
Inverter
rated
current
0 to 500 A
Set the rated motor current.
83
C104
Rated motor voltage
200/400/
575 V
0 to 1000 V
Set the rated motor voltage (V).
84
C105
Rated motor frequency
9999
10 to 400 Hz
Set the rated motor frequency (Hz).
9999
Inverter internal data is used.
702
C106
Maximum motor frequency
9999
0 to 400 Hz
Set the permissible speed (frequency) of the motor.
9999
The
Pr.84
setting is used.
707
C107
Motor inertia (integer)
9999
10 to 999, 9999
Set the motor inertia.
9999: Inverter internal data is used.
724
C108
Motor inertia (exponent)
9999
0 to 7, 9999
96
C110
Auto tuning setting/status
0
0
No offline auto tuning
1
Offline auto tuning is performed without the motor rotating.
11
Offline auto tuning is performed without the motor rotating
(under V/F control).
90
C120
Motor constant (R1)
9999
0 to 50
Ω
, 9999
Tuning data (The value measured by offline auto tuning is
automatically set.)
9999: Inverter internal data is used.
92
C122
Motor constant (L1)/d-axis
inductance (Ld)
9999
0 to 500 mH, 9999
93
C123
Motor constant (L2)/q-axis
inductance (Lq)
9999
0 to 500 mH, 9999
859
C126
Torque current/Rated PM
motor current
9999
0 to 500 A, 9999
706
C130
Induced voltage constant
(phi f)
9999
0 to 5000 mV (rad/s)
Set this parameter according to the PM motor
specifications.
9999
The value calculated from the parameter setting for motor
constant is used.
1412
C135
Motor induced voltage
constant (phi f) exponent
9999
0 to 2
Set the exponent n when the induced voltage constant phi
f (
Pr.706
) is multiplied by 10
n
.
9999
No exponent setting
PM
PM
PM
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...