357
14. (C) Motor Constant Parameters
14.3 Offline auto tuning for a PM motor (motor constant tuning)
*1
The setting range for the 575 V class is "0, 3, 5, 6, 10, 13, 15, 16, 30, 33, 8090, 8093, 9090, and 9093".
*2
The initial value for the FR-E820-0050(0.75K) or lower, the FR-E840-0026(0.75K) or lower, the FR-E860-0017(0.75K), and the FR-E820S-
0050(0.75K) or lower is set to the 85% of the inverter rated current.
*3
The initial value differs according to the voltage class (200/400/575 V).
*4
The setting range and unit change according to the
Pr.71 (Pr.450)
setting.
• The settings are valid under PM sensorless vector control.
• The offline auto tuning enables the operation with IPM motors and SPM motors. (When a PM motor is used, always perform
offline auto tuning.)
• Tuning is enabled even when a load is connected to the motor.
• Reading/writing of the motor constants tuned by offline auto tuning are enabled.
• The offline auto tuning status can be monitored on the operation panel.
Before performing offline auto tuning
Check the following points before performing offline auto tuning:
• Check that PM sensorless vector control is selected. (Refer to
• Check that a motor is connected. (Check that the motor is not rotated by an external force during tuning.)
• The rated motor current should be equal to or less than the inverter rated current. (Note that the motor rated current should
be 0.4 kW or higher (0.1 kW or higher for the 200 V class).)
If a motor with substantially low rated current compared with the inverter rated current, however, is used, speed and torque
accuracies may deteriorate due to torque ripples, etc. Set the rated motor current to about 40% or higher of the inverter
rated current.
• The maximum frequency under PM sensorless vector control is 400 Hz.
• Tuning is enabled even when a load is connected to the motor. The motor may run slightly. Fix the motor securely with a
mechanical brake, or before tuning, make sure that it is safe even if the motor rotates. (Caution is required especially in
vertical lift applications.) Note that even if the motor runs slightly, tuning performance is unaffected.
• Tuning may be disabled depending on the motor characteristics.
Settings
• To perform tuning, set the following parameters about the motor.
739
C231
Second motor Ld decay
ratio
9999
0% to 100%, 9999
Tuning data of the second motor.
(The value measured by offline auto tuning is automatically
set.)
9999: Inverter internal data is used.
740
C232
Second motor Lq decay
ratio
9999
0% to 100%, 9999
741
C282
Second motor starting
resistance tuning
compensation coefficient 1
9999
0% to 200%, 9999
742
C285
Second motor magnetic
pole detection pulse width
9999
0 to 6000
μ
s, 9999
746
C233
Second motor protection
current level
9999
100% to 500%
Set the maximum current (OCT) level of the second motor.
9999
200%
Pr.
Name
Initial
value
Setting range
Description
First motor Pr. Second motor Pr.
Name
Setting
80
453
Motor capacity
Motor capacity (kW)
81
454
Number of motor poles
Number of motor poles (2 to 12)
9
51
Electronic thermal O/L relay
Rated motor current (A)
84
457
Rated motor frequency
Rated motor frequency (Hz)
83
456
Rated motor voltage
Rated motor voltage (V)
71
450
Applied motor
8090, 8093 (IPM motor),
9090, 9093 (SPM motor)
96
463
Auto tuning setting/status
1
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...