169
8. (E) Environment Setting Parameters
8.7 Frequency change increment amount setting (standard model)
1
2
3
4
5
6
7
8
9
10
8.7
Frequency change increment amount setting
(standard model)
When setting the set frequency with the setting dial of the operation panel, the frequency changes in 0.01 Hz increments in the
initial status. Setting this parameter to increase the frequency increment amount that changes when the setting dial is rotated
can improve usability.
Basic operation
• When
Pr.295
≠
"0", the minimum increment when the set frequency is changed with the setting dial can be set.
For example, when
Pr.295
= 1.00 Hz, one click (one dial gauge) of the setting dial changes the frequency in increments
of 1.00 Hz, such as 1.00 Hz
→
2.00 Hz
→
3.00 Hz.
NOTE
• When machine speed display is selected in
Pr.53 Frequency / rotation speed unit switchover
, the minimum increments of
change are determined by
Pr.295
as well. Note that the setting value may differ as speed setting changes the set machine
speed and converts it to the speed display again.
• For
Pr.295
, the increments are not displayed.
• The
Pr.295
setting is enabled only for the changes to the set frequency. It does not apply to the settings of other parameters
related to frequency.
• When 10 is set, the frequency setting changes in 10 Hz increments. Be cautious of excessive speed (when Automatic
frequency setting enabled).
Parameters referred to
Pr.53 Frequency / rotation speed unit switchover
Pr.
Name
Initial value
Setting range
Description
295
E201
Frequency change
increment amount setting
0
0
Function disabled
0.01
The minimum change width when the set frequency is
changed with the setting dial can be set.
0.10
1.00
10.00
When
Pr.295
="1.00"
1 click
1 click
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...