112
5. Speed Control
5.2 Setting procedure of Vector control (speed control)
5.2
Setting procedure of Vector control (speed control)
Operating procedure
1.
Perform wiring properly. (Refer to the Instruction Manual (Connection).)
Install a Vector control compatible option.
2.
Set the applied motor and encoder (
Pr.71, Pr.359, Pr.369
). (Refer to
3.
Set the overheat protection of the motor (
Pr.9
). (Refer to
.)
When using the SF-V5RU or a motor equipped with a thermal sensor, set
Pr.9
= 0 A. For details on connecting a
motor equipped with a thermal sensor, refer to the Instruction Manual (Connection).
4.
Set the motor capacity and number of motor poles (
Pr.80, Pr.81
.)
V/F control is performed when the setting is "9999" (initial value).
5.
Set the rated motor voltage and the rated motor frequency (
Pr.83, Pr.84
6.
Select the control method (
Pr.800
Select
Pr.800
= "0" (speed control) or "2" (speed/torque switchover) to enable speed control.
7.
Set the operation command. (Refer to
.)
Select the start command and speed command.
8.
Set the torque limit (
Pr.810
). (Refer to
.)
9.
Perform the test operation.
As required
• Perform offline auto tuning
(Pr.96)
. (Refer to
• Select online auto tuning (
Pr.95
.)
NOTE
• Under Vector control, the magnetic flux observer is enabled to estimate or measure the flux within the motor using the current
running through the motor and the inverter output voltage. This improves the torque accuracy since the flux of a motor can be
accurately estimated and optimum characteristics can be obtained without being affected by temperature change in the
second resistor.
• The speed command setting range under Vector control is 0 to 400 Hz.
• The carrier frequency is limited during Vector control. (Refer to
.)
Vector
Vector
Vector
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...