318
13. (T) Multi-Function Input Terminal Parameters
13.4 Frequency setting voltage (current) bias and gain
13.4
Frequency setting voltage (current) bias and gain
The magnitude (slope) of the output frequency can be set as desired in relation to the frequency setting signal (0 to 5 VDC, 0
to 10 VDC, or 4 to 20 mA). Use
Pr.73 Analog input selection (Pr.267 Terminal 4 input selection)
and the voltage/current
input selection switch to switch among input of 0 to 5 VDC, 0 to 10 V, and 0 to 20 mA. (Refer to
.)
*1
On the LCD operation panel used as the command source, the parameter number in parentheses appears instead of that starting with the letter C.
*2
Gr.1 and Gr.2 are the parameter initial value groups. (Refer to
Relationship between the analog input terminal function and the
calibration parameter
• Calibration parameter according to the terminal 4 function
Changing the frequency for the maximum analog input (Pr.125, Pr.126)
• Use
Pr.125 (Pr.126)
to change the frequency setting (gain) for the maximum analog input voltage (current).
(
C2 (Pr.902) to C7 (Pr.905)
settings need not be changed.)
Analog input bias/gain calibration (C2 (Pr.902) to C7 (Pr.905))
• The "bias" and "gain" functions serve to adjust the relationship between a setting input signal and the output frequency. A
setting input signal is such as a 0 to 5 VDC, 0 to 10 VDC, or 4 to 20 mADC signal externally input to set the output
frequency.
• Set the bias frequency of the terminal 2 input using
C2 (Pr.902)
. (It is initially set to the frequency at 0 V.)
Pr.
Name
Initial value
Setting
range
Description
Gr.1
Gr.2
C2 (902)
T200
Terminal 2 frequency setting
bias frequency
0 Hz
0 to 590 Hz Set the bias frequency for the terminal 2 input.
C3 (902)
T201
Terminal 2 frequency setting
bias
0%
0% to
300%
Set the converted % of the bias voltage (current) for the terminal
2 input.
125 (903)
T202
T022
Terminal 2 frequency setting
gain frequency
60 Hz 50 Hz 0 to 590 Hz Set the gain (maximum) frequency for the terminal 2 input.
C4 (903)
T203
Terminal 2 frequency setting
gain
100%
0% to
300%
Set the converted % of the gain voltage (current) for the terminal
2 input.
C5 (904)
T400
Terminal 4 frequency setting
bias frequency
0 Hz
0 to 590 Hz Set the bias frequency for the terminal 4 input.
C6 (904)
T401
Terminal 4 frequency setting
bias
20%
0% to
300%
Set the converted % of the bias current (voltage) for the terminal
4 input.
126 (905)
T402
T042
Terminal 4 frequency setting
gain frequency
60 Hz 50 Hz 0 to 590 Hz Set the gain (maximum) frequency for the terminal 4 input.
C7 (905)
T403
Terminal 4 frequency setting
gain
100%
0% to
300%
Set the converted % of the gain current (voltage) for the terminal
4 input.
241
M043
Analog input display unit
switchover
0
0
% display
Select the unit for analog input display.
1
V/mA display
Pr.858
setting
Terminal function
Calibration parameter
Bias setting
Gain setting
0 (initial
value)
Frequency command
C5 (Pr.904) Terminal 4 frequency setting bias
frequency
C6 (Pr.904) Terminal 4 frequency setting bias
Pr.126 Terminal 4 frequency setting gain
frequency
C7 (Pr.905) Terminal 4 frequency setting gain
4
Torque limit
C38 (Pr.932) Terminal 4 bias command (torque/
magnetic flux)
C39 (Pr.932) Terminal 4 bias (torque/magnetic
flux)
C40 (Pr.933) Terminal 4 gain command (torque/
magnetic flux)
C41 (Pr.933) Terminal 4 gain (torque/magnetic
flux)
6
Torque bias input
C38 (Pr.932) Terminal 4 bias command (torque/
magnetic flux),
C39 (Pr.932) Terminal 4 bias (torque/magnetic
flux)
C40 (Pr.933) Terminal 4 gain command (torque/
magnetic flux)
C41 (Pr.933) Terminal 4 gain (torque/magnetic
flux)
9999
No function
—
—
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...