Extended parameter display and user group
function
Use this parameter to select a group of parameters to be displayed on the operation panel.
*1
The read value is always "9999".
Display of simple mode parameters and extended parameters (Pr.160)
• When
Pr.160
= "9999", only the simple mode parameters can be displayed on the operation panel. (For the simple mode
parameters, refer to the parameter list on
• With the initial value (
Pr.160
= "0", simple mode parameters and extended parameters can be displayed.
NOTE
• When a plug-in option in installed on the inverter, the option parameters can also be read.
• Every parameter can be read regardless of the
Pr.160
setting when reading parameters via communication.
• When the LCD operation panel (FR-LU08) or parameter unit (FR-PU07) is installed,
Pr.15 Jog frequency, Pr.16 Jog
acceleration/deceleration time, C42 (Pr.934) PID display bias coefficient, C43 (Pr.934) PID display bias analog value,
C44 (Pr.935) PID display gain coefficient, C45 (Pr.935) PID display gain analog value, and Pr.991 PU contrast
adjustment
are displayed as simple mode parameters.
User group function (Pr.160, Pr.172 to Pr.174)
• The user group function is a function for displaying only the parameters required for a setting.
• A maximum of 16 parameters from any of the parameters can be registered in a user group. When
Pr.160
= "1", reading/
writing is enabled only for the parameters registered in user groups. (Parameters not registered in user groups can no
longer be read.)
• To register a parameter in a user group, set the parameter number in
Pr.173
.
• To clear a parameter from a user group, set the parameter number in
Pr.174
. To batch clear all the registered parameters,
set
Pr.172
= "9999".
Pr.
Name
Initial value
Setting range
Description
160
E440
User group read
selection
0
9999
Only simple mode parameters are displayed.
0
Displays simple mode and extended parameters.
1
Only parameters registered in user groups are displayed.
172
E441
User group registered
display/batch clear
0
(0 to 16)
Displays the number of parameters that are registered in the
user groups. (Read-only)
9999
Batch clear of user group registrations
173
E442
User group registration
0 to 1999, 9999 Sets the parameter number to register for the user group.
174
E443
User group clear
0 to 1999, 9999 Sets the parameter number to clear from the user group.
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...