14. (C) Motor Constant Parameters
14.2 Offline auto tuning
*2
For the settings for the SF-V5RU, refer to
*3
Set
Pr.71 Applied motor
according to the motor to be used and the motor constant setting range. According to the
Pr.71
setting, the range of
the motor constant parameter setting values and units can be changed. (For other setting values of
Pr.71
, refer to
• 200/400 V class
• 575 V class
NOTE
• When
Pr.11 DC injection brake operation time
= "0" or
Pr.12 DC injection brake operation voltage
= "0", offline auto
tuning is performed at the initial setting of
Pr.11
or
Pr.12
.
• If "wye connection" or "delta connection" is incorrectly selected in
Pr.71
, Advanced magnetic flux vector control, Real
sensorless vector control, and Vector control are not performed properly.
• To perform offline auto tuning for the 400 V class 0.1 kW Mitsubishi Electric geared motor (GM-[]), set "1803" in
Pr.71 (Pr.450)
.
Motor
Pr.71 setting
Motor constant
parameter mH, %, and
A unit setting
Motor constant
parameter internal
data setting
Motor constant
parameter
Ω
, m
Ω
, and
A unit setting
Mitsubishi Electric high-
performance energy-
saving motor
SF-PR
70
73
—
Mitsubishi Electric high-
performance energy-
saving motor with
encoder
SF-PR-SC
Mitsubishi Electric Vector
control dedicated motor
SF-V5RU (1500 r/min series)
30
33
—
Mitsubishi Electric geared
motor
GM-[]
1800
1803
—
Mitsubishi Electric
inverter-driven geared
motor for encoder
feedback control
GM-DZ, GM-DP
Mitsubishi Electric
standard efficiency motor
Mitsubishi Electric high-
efficiency motor
SF-JR
0 (initial value)
3
—
SF-JR 4P 1.5 kW or lower
20
23
—
SF-HR
40
43
—
Others
0 (initial value)
3
—
Mitsubishi Electric
constant-torque motor
SF-JRCA 4P
10
13
—
SF-HRCA
50
53
—
Others (SF-JRC, etc.)
10
13
—
Other manufacturer's
standard motor
—
0 (initial value)
3
5 (wye connection
motor)
6 (delta connection
motor)
Other manufacturer's
constant-torque motor
—
10
13
15 (wye connection
motor)
16 (delta connection
motor)
Motor
Pr.71 setting
Motor constant
parameter mH, %, and
A unit setting
Motor constant
parameter internal
data setting
Motor constant
parameter
Ω
, m
Ω
, and
A unit setting
Vector control dedicated motor
30
33
—
Standard motor
0 (initial value)
3
—
Constant-torque motor
10
13
—
Other manufacturer's standard motor
0 (initial value)
3
5 (wye connection
motor)
6 (delta connection
motor)
Other manufacturer's constant-torque motor
10
13
15 (wye connection
motor)
16 (delta connection
motor)
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...