8. (E) Environment Setting Parameters
8.14 Extended parameter display and user group function
1
2
3
4
5
6
7
8
9
10
Clearing a parameter from a user group (Pr.174)
• To delete
Pr.3
from a user group.
Operating procedure
1.
Power ON
Make sure the motor is stopped.
2.
Changing the operation mode
Press the PU/EXT key to choose the PU operation mode. The PU LED turns ON.
3.
Selecting the parameter setting mode
Press the MODE key to choose the parameter setting mode. (The parameter number read previously appears.)
4.
Selecting a parameter
Turn the setting dial or press the UP/DOWN key until "P.174" (
Pr.174
) appears.
5.
Parameter read
Press the SET key. "9999" appears.
6.
Clearing the parameter
Turn the setting dial or press the UP/DOWN key until "3" (
Pr.3
) appears. Press the SET key to delete the parameter.
"3" blinks.
To continue deleting parameters, repeat steps 5 and 6.
NOTE
•
Pr.77 Parameter write selection, Pr.160, Pr.296 Password lock level, Pr.297 Password lock/unlock, and Pr.991 PU
contrast adjustment
can always be read regardless of the user group setting. (For
Pr.991
, only when the FR-LU08 or the
FR-PU07 is connected.)
•
Pr.77, Pr.160, Pr.172 to Pr.174, Pr.296, and Pr.297
cannot be registered in a user group.
• When
Pr.174
is read, "9999" is always displayed. "9999" can be written, but it does not function.
•
Pr.172
is disabled if set to a value other than "9999".
Parameters referred to
Pr.77 Parameter write selection
Pr.296 Password lock level, Pr.297 Password lock/unlock
Pr.991 PU contrast adjustment
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...