Password
Registering a 4-digit password can restrict access to parameters (reading/writing).
These parameters can be set when
Pr.160 User group read selection
= "0". However, when
Pr.296
≠
9999 (password lock
is set),
Pr.297
can always be set, regardless of the setting in
Pr.160
.
*1
Although "0 or 9999" can be input in
Pr.297
, the value is invalid. (The display cannot be changed.)
Parameter reading/writing restriction level (Pr.296)
• The access (reading/writing) restriction level to parameters in the PU operation mode or NET operation mode can be
selected with
Pr.296
.
○
: Enabled, ×: Disabled
*1
If the parameter reading is restricted by the setting of
Pr.160 User group read selection
, those parameters cannot be read even when "
○
" is
indicated.
*2
If the parameter writing is restricted by the setting of
Pr.77 Parameter write selection
, those parameters cannot be written even when "
○
" is
indicated.
*3
Access from the command source in the PU operation mode (the operation panel in the initial setting) is restricted. (For the PU operation mode
command source selection, refer to
.)
*4
Access from the command source in the Network operation mode (the RS-485 communication or a communication option in the initial setting) is
restricted. (For the NET operation mode command source selection, refer to
.)
*5
Read/write is enabled only for the simple mode parameters registered in the user group when
Pr.160
= "9999".
Pr.296 and Pr.297
are always
read/write enabled whether registered to a user group or not.
*6
If a communication option is installed, the Option fault (E.OPT) occurs, and the inverter output shuts off.
*7
The PLC function user parameters (
Pr.1150 to Pr.1199
) can be written and read by the PLC function regardless of the
Pr.296
setting.
Locking parameters with a password (Pr.296, Pr.297)
• The procedure of locking parameters with a password is as follows.
1.
Set the parameter reading/writing restriction level to enable the password protection. (Set a value other than "9999"
in
Pr.296
.)
Pr.
Name
Initial value
Setting range
Description
296
E410
Password lock level
9999
0 to 6, 99, 100 to
106, 199
Password protection enabled. Setting the access
(reading/writing) restriction level to parameters locked
with a password enables writing to
Pr.297
.
9999
No password protection
297
E411
Password lock/unlock
9999
1000 to 9998
Input a 4-digit password to lock parameters, or input the
valid password to unlock the locked parameters.
(0 to 5)
Number of failed password attempts (read only,
displayed after any of "100 to 106, or 199" is set in
Pr.296
and a password to lock parameters is input).
No password protection
Pr.296 setting
PU operation mode operation
command
NET operation mode operation command
RS-485 communication / PLC
function
via communication option
Write
Read
Write
Read
Write
9999
○
○
○
○
○
○
0, 100
×
×
×
×
×
×
1, 101
○
×
○
×
○
×
2, 102
○
×
○
○
○
○
3, 103
○
○
○
×
○
×
4, 104
×
×
×
×
○
×
5, 105
×
×
○
○
○
○
6, 106
○
○
×
×
○
×
99, 199
Only the parameters registered in the user group can be read/written. (For the parameters not registered in the user
group, the restriction level when "4 or 104" is set applies.)
Pr.296 setting
Allowable number of failed password
attempts
Pr.297 readout
0 to 6, or 99
Unlimited
Always 0
100 to 106, 199
Limited to 5 times
Number of failed password attempts (0 to 5)
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...