346
14. (C) Motor Constant Parameters
14.2 Offline auto tuning
298
A711
Frequency search
gain
9999
0 to 32767
The offline auto tuning automatically sets the gain required for
the frequency search.
9999
The constant value of Mitsubishi Electric motor (SF-PR, SF-
PR-SC, SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU (1500
r/min series), GM-[], GM-DZ, or GM-DP) is used.
450
C200
Second applied
motor
9999
0, 3, 5, 6, 10, 13, 15, 16, 20,
23, 30, 33, 40, 43, 50, 53,
70, 73, 1800
, 1803, 8090,
8093, 9090, 9093
Set this parameter when using the second motor
(the same specifications as
Pr.71
).
9999
The function is disabled.
453
C201
Second motor
capacity
9999
0.1 to 30 kW
Set the capacity of the second motor.
9999
V/F control
454
C202
Number of second
motor poles
9999
2, 4, 6, 8, 10, 12
Set the number of poles of the second motor.
9999
V/F control
51
C203
Second electronic
thermal O/L relay
9999
0 to 500 A
This function is enabled when the RT signal is ON.
Set the rated motor current.
9999
Second electronic thermal O/L relay disabled.
456
C204
Rated second motor
voltage
200/400/
575 V
0 to 1000 V
Set the rated voltage (V) of the second motor.
457
C205
Rated second motor
frequency
9999
10 to 400 Hz
Set the rated frequency (Hz) of the second motor.
9999
The
Pr.84 Rated motor frequency
setting is used.
744
C207
Second motor
inertia (integer)
9999
10 to 999, 9999
Set the inertia of the second motor.
9999: The constant value of Mitsubishi Electric motor (SF-PR,
SF-PR-SC, SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU
(1500 r/min series), GM-[], GM-DZ, or GM-DP) is used.
745
C208
Second motor
inertia (exponent)
9999
0 to 7, 9999
463
C210
Second motor auto
tuning setting/
status
0
0
No auto tuning for the second motor.
1
Offline auto tuning is performed without the second motor
rotating.
11
Offline auto tuning is performed without the second motor
rotating (under V/F control). (Refer to
458
C220
Second motor
constant (R1)
9999
0 to 50
Ω
, 9999
Tuning data of the second motor.
(The value measured by offline auto tuning is automatically
set.)
9999: The constant value of Mitsubishi Electric motor (SF-PR,
SF-PR-SC, SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU
(1500 r/min series), GM-[], GM-DZ, or GM-DP) is used.
459
C221
Second motor
constant (R2)
9999
0 to 50
Ω
, 9999
460
C222
Second motor
constant (L1) / d-
axis inductance (Ld)
9999
0 to 6000 mH, 9999
461
C223
Second motor
constant (L2) / q-
axis inductance (Lq)
9999
0 to 6000 mH, 9999
462
C224
Second motor
constant (X)
9999
0% to 100%, 9999
455
C225
Second motor
excitation current
9999
0 to 500 A, 9999
860
C226
Second motor
torque current/
Rated PM motor
current
9999
0 to 500 A, 9999
741
C282
Second motor
starting resistance
tuning
compensation
coefficient 1
9999
0% to 200%, 9999
737
C288
Starting resistance
tuning
compensation
coefficient 2
9999
0% to 200%, 9999
560
A712
Second frequency
search gain
9999
0 to 32767
The offline auto tuning automatically sets the gain required for
the frequency search of the second motor.
9999
The constant value of Mitsubishi Electric motor (SF-PR, SF-
PR-SC, SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU (1500
r/min series), GM-[], GM-DZ, or GM-DP) is used for the second
motor.
Pr.
Name
Initial
value
Setting range
Description
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...