12. (M) Item and Output Signal for Monitoring
12.2 Monitor item selection on operation panel or via communication
•
Pr.774
sets the output frequency monitor,
Pr.775
sets the output current monitor, and
Pr.776
sets the monitor description
to be displayed at the output voltage monitor position. When
Pr.774 to Pr.776
= "9999" (initial value), the
Pr.52
setting
value is used.
NOTE
• On the operation panel, the Hz LED is lit while displaying the output frequency, the Hz LED blinks when displaying the set
frequency.
• When the operation panel is used, the displayed units are Hz and A only, and the others are not displayed.
Displaying the set frequency during stop (Pr.52)
• When
Pr.52
= "100", the set frequency is displayed during stop, and output frequency is displayed during running. (The Hz
LED blinks during stop and is lit during operation.)
*1
Displays the frequency that is output when the start command is ON. The value considers the maximum/minimum frequency and frequency
jumps. It is different from the frequency setting displayed when
Pr.52
= "5".
NOTE
• During an error, the output frequency at error occurrence appears.
• During output shutoff by the MRS signal, the values displayed are the same as during a stop.
• During offline auto tuning, the tuning state monitor takes priority.
Operation panel setting dial push display (Pr.992) (only for the standard
model)
• Use
Pr.992
to select the monitor that appears when the setting dial on the operation panel is pushed.
• When
Pr.992
= "0 (initial value)", keep pressing the setting dial when in PU operation mode or External/PU combined
operation mode 1 (
Pr.79 Operation mode selection
= "3") to show the presently set frequency.
• When
Pr.992
= "100", the set frequency is displayed during stop, and output frequency is displayed during running.
*1
Displays the frequency that is output when the start command is ON. The value considers the maximum/minimum frequency and frequency
jumps. It is different from the frequency setting displayed when
Pr.992
= "5".
Monitoring I/O terminals on the operation panel (Pr.52, Pr.774 to Pr.776,
Pr.992)
• When
Pr.52 (Pr.774 to Pr.776, Pr.992)
= "55 to 57", the I/O terminal state can be monitored on the operation panel.
• When a terminal is ON, the corresponding LED segment is ON. The center LED segments are always ON.
*1
The setting value "56 or 57" can be set even if the option is not installed. All are OFF when the option is not connected.
Pr.52 setting
Status
Output frequency
Output current
Output voltage
Fault monitor
0
During running/stop
Output frequency
Output current
Output voltage
Fault monitor
100
During stop
Set frequency
During running
Output frequency
Pr.992 setting
Status
Monitor displayed by the setting dial push
0
During running/stop
Set frequency
100
During stop
Set frequency
During running
Output frequency
Pr.52, Pr.774 to Pr.776,
Pr.992 setting
Monitor item
Monitor description
55
I/O terminal status
Displays the I/O terminal ON/OFF state of the inverter.
56
Option input terminal status
Displays input terminal ON/OFF state of the digital input option (FR-A8AX)
57
Option output terminal status
Displays output terminal ON/OFF state of the digital output option (FR-A8AY) or
the relay output option (FR-A8AR).
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...