180
8. (E) Environment Setting Parameters
8.13 Setting multiple parameters by batch
Initial setting with the GOT2000 series
• When "FREQROL 500/700/800, SENSORLESS SERVO" is selected for "Controller Type" in the GOT setting, set
Pr.999
= "10" to configure the GOT initial setting.
• When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT setting, the GOT automatic
connection can be used. When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT
setting and the GOT automatic connection is not used, set
Pr.999
= "12" to configure the GOT initial setting. (Refer to the
Instruction Manual (Communication).)
Initial setting with the GOT1000 series
• Set
Pr.999
= "10" to configure the GOT initial setting.
NOTE
• Always perform an inverter reset after the initial setting.
• For the details of connection with GOT, refer to the Instruction Manual of GOT.
Rated frequency (Pr.999 = "20" (50 Hz) or "21" (60 Hz))
*1
Gr.1 and Gr.2 are the parameter initial value groups. (Refer to
*2
Refer to the Instruction Manual (Communication).
NOTE
• When the plug-in option FR-A8AX is used,
Pr.301 BCD input gain
and
Pr.303 BIN input gain
are not set automatically.
Pr.
Name
Initial value
Pr.999 = "21"
Pr.999 = "20"
Refer to
page
Gr.1
Gr.2
3
Base frequency
60 Hz
50 Hz
60 Hz
50 Hz
4
Multi-speed setting (high speed)
60 Hz
50 Hz
60 Hz
50 Hz
20
Acceleration/deceleration reference
frequency
60 Hz
50 Hz
60 Hz
50 Hz
53
Frequency / rotation speed unit
switchover
0
0
55
Frequency monitoring reference
60 Hz
50 Hz
60 Hz
50 Hz
66
Stall prevention operation reduction
starting frequency
60 Hz
50 Hz
60 Hz
50 Hz
125
Terminal 2 frequency setting gain
frequency
60 Hz
50 Hz
60 Hz
50 Hz
126
Terminal 4 frequency setting gain
frequency
60 Hz
50 Hz
60 Hz
50 Hz
390
% setting reference frequency
60 Hz
50 Hz
60 Hz
50 Hz
505
Speed setting reference
60 Hz
50 Hz
60 Hz
50 Hz
808
Speed limit
60 Hz
50 Hz
60 Hz
50 Hz
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...