234
10. (D) Operation Command and Frequency Command
10.6 Operation by multi-speed setting
10.6
Operation by multi-speed setting
Use these parameters to change among pre-set operation speeds with the terminals. The speeds are pre-set with parameters.
Any speed can be selected by simply turning ON/OFF the contact signals (RH, RM, RL, and REX signals).
*1
Gr.1 and Gr.2 are the parameter initial value groups. (Refer to
Multi-speed setting (Pr.4 to Pr.6)
• The inverter operates at frequencies set in
Pr.4
when the RH signal is ON,
Pr.5
when the RM signal is ON, or
Pr.6
when
the RL signal is ON.
NOTE
• In the initial setting, if two or more speed switches (signals) are simultaneously turned ON, priority is given to the switch (signal)
for the lower speed. For example, when both RH and RM signals turn ON, the RM signal (
Pr.5
) has the higher priority.
• The RH, RM and RL signals are assigned to the terminals RH, RM and RL, respectively, in the initial status. To assign each
signal to a different terminal, set "0" (RL signal), "1" (RM signal), or "2" (RH signal) in any of
Pr.178 to Pr.189 (Input terminal
function selection)
.
Pr.
Name
Initial value
Setting range
Description
Gr.1
Gr.2
4
D301
Multi-speed setting (high speed)
60 Hz
50 Hz
0 to 590 Hz
Sets the frequency when RH is ON.
5
D302
Multi-speed setting (middle
speed)
30 Hz
0 to 590 Hz
Sets the frequency when RM is ON.
6
D303
Multi-speed setting (low speed)
10 Hz
0 to 590 Hz
Sets the frequency when RL is ON.
24
D304
Multi-speed setting (speed 4)
9999
0 to 590 Hz, 9999
Frequency from 4th speed to 15th speed can
be set according to the combination of the RH,
RM, RL and REX signals.
9999: Not selected
25
D305
Multi-speed setting (speed 5)
26
D306
Multi-speed setting (speed 6)
27
D307
Multi-speed setting (speed 7)
232
D308
Multi-speed setting (speed 8)
233
D309
Multi-speed setting (speed 9)
234
D310
Multi-speed setting (speed 10)
235
D311
Multi-speed setting (speed 11)
236
D312
Multi-speed setting (speed 12)
237
D313
Multi-speed setting (speed 13)
238
D314
Multi-speed setting (speed 14)
239
D315
Multi-speed setting (speed 15)
Forward rotation start
RM
STF
STR
RH
SD
RL
Inverter
Switch
Reverse rotation start
High speed
Middle speed
Low speed
ON
ON
ON
Output frequency (Hz)
Speed 1
(High speed)
Speed 2
(Middle speed)
Speed 3
(Low speed)
Time
RH
RM
RL
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...