72
3. Parameters
3.2 Parameter list (by parameter number)
Pr.1100 to Pr.1399
Trace
1020
A900
Trace operation selection
0 to 3
1
0
1022
A902
Sampling cycle
1, 2, 5, 10, 50, 100,
500, 1000
1
1
1023
A903
Number of analog channels
1 to 8
1
4
1024
A904
Sampling auto start
0, 1
1
0
1025
A905
Trigger mode selection
0 to 4
1
0
1026
A906
Number of sampling before
trigger
0% to 100%
1%
90%
1027
A910
Analog source selection
(1ch)
1 to 3, 5 to 14, 17 to 20,
23, 24, 32, 33, 35, 40
to 42, 52 to 54, 61, 62,
67, 83 [E800-
(SC)EPA], 91, 97, 201
to 210, 212, 213, 230
to 232, 235 to 238
1
201
1028
A911
Analog source selection
(2ch)
202
1029
A912
Analog source selection
(3ch)
203
1030
A913
Analog source selection
(4ch)
204
1031
A914
Analog source selection
(5ch)
205
1032
A915
Analog source selection
(6ch)
206
1033
A916
Analog source selection
(7ch)
207
1034
A917
Analog source selection
(8ch)
208
1035
A918
Analog trigger channel
1 to 8
1
1
1036
A919
Analog trigger operation
selection
0, 1
1
0
1037
A920
Analog trigger level
600 to 1400
1
1000
1038
A930
Digital source selection (1ch)
0 to 255
1
0
1039
A931
Digital source selection (2ch)
0
1040
A932
Digital source selection (3ch)
0
1041
A933
Digital source selection (4ch)
0
1042
A934
Digital source selection (5ch)
0
1043
A935
Digital source selection (6ch)
0
1044
A936
Digital source selection (7ch)
0
1045
A937
Digital source selection (8ch)
0
1046
A938
Digital trigger channel
1 to 8
1
1
1047
A939
Digital trigger operation
selection
0, 1
1
0
Function
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial
value
*1
Refer
to page
Customer
setting
Gr.1
Gr.2
Function
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial
value
Refer
to page
Customer
setting
Gr.1
Gr.2
—
1103
F040
Deceleration time at
emergency stop
0 to 3600 s
0.1 s
5 s
Monit
o
rin
g
1106
M050
Torque monitor filter
0 to 5 s, 9999
0.01 s
9999
1107
M051
Running speed monitor filter
0 to 5 s, 9999
0.01 s
9999
1108
M052
Excitation current monitor
filter
0 to 5 s, 9999
0.01 s
9999
—
1124
N681
Station number in inverter-to-
inverter link
[E800-(SC)E]
0 to 5, 9999
1
9999
—
1125
N682
Number of inverters in
inverter-to-inverter link
system
[E800-(SC)E]
2 to 6
1
2
PL
C fu
nct
ion
1150 to
1199
A810 to
A859
PLC function user
parameters 1 to 50
0 to 65535
1
0
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...