463
18. Appendix
18.2 Specification change
18.2
Specification change
Check the SERIAL number indicated on the inverter rating plate or packaging. For how to read the SERIAL number, refer to
18.2.1 Details of changes
Number of connectable units on the CC-Link IE Field Network Basic
Functions available for the inverters manufactured in May 2020 or later
Functions available for the inverters manufactured in August 2020 or
later
Number of connectable units
SERIAL (serial number)
Master: 1
Slave: up to 16 stations (16 stations × 1 group)
□□
204
○○○○○○
or earlier
Master: 1
Slave: up to 16 stations (16 stations × 4 groups)
□□
205
○○○○○○
or later
Item
Change
Mitsubishi Electric geared motor
GM-[]
Plug-in option
FR-A8ND E kit, FR-A8NP E-kit
Stand-alone option
Parameter unit (FR-PU07), LCD operation panel (FR-LU08)
Added parameters
Pr.1499, P.E107 (Pr.75)
Changed parameter setting range
• Setting value "13" added for
Pr.52, Pr.54, Pr.158, Pr.774 to Pr.776, Pr.992, and Pr.1027 to
Pr.1034
• Setting values "1800 and 1803" added for
Pr.71 and Pr.450
(for 200/400 V class only)
• Setting values "10000 to 10003 and 10014 to 10017" added for
Pr.75
(for the safety
communication model only)
Item
Change
Mitsubishi Electric Vector control
dedicated motor (SF-V5RU (1500 r/min
series))
The SF-V5RU 1.5 to 5.5 kW motors can be driven by the FR-E820-0110(2.2K) to 0330(7.5K)
inverters.
The SF-V5RUH 1.5 to 5.5 kW motors can be driven by the FR-E840-0060(2.2K) to 0170(7.5K)
inverters.
Mitsubishi Electric high-performance
energy-saving motor with encoder
SF-PR-SC
Mitsubishi Electric inverter-driven geared
motor for encoder feedback control
GM-DZ, GM-DP
Plug-in option
FR-A8AP E kit
Added parameters
Pr.284, Pr.359, Pr.367, Pr.368, Pr.369, Pr.376, Pr.422, Pr.552, Pr.600 to Pr.604, Pr.607,
Pr.608, Pr.690, Pr.692 to Pr.696, Pr.802, Pr.823, Pr.828, Pr.833, Pr.840 to Pr.848, Pr.854,
Pr.873, Pr.877 to Pr.881, P.A107 (Pr.285)
Changed parameter setting range
• Setting value "8888" added for
Pr.11
• Setting values "19 and 35" added for
Pr.52, Pr.774 to Pr.776, Pr.992, and Pr.1027 to Pr.1034
• Setting values "30 and 33" added for
Pr.71 and Pr.450
• Setting values "13, 23, 42, 43, and 74" added for
Pr.178 to Pr.189
• Setting values "30 to 33 and 130 to 133" added for
Pr.190 to Pr.196, and Pr.313 to Pr.319
• Setting values "30 to 33" added for
Pr.320 to Pr.322
• Setting values "0 to 2 and 9" added for
Pr.800
• Setting value "2" added for
Pr.850
• Setting value "6" added for
Pr.858
Added faults
• Signal loss detection (E.ECT)
• Brake sequence fault (E.MB1 to E.MB3)
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...