224
10. (D) Operation Command and Frequency Command
10.3 Start command source and frequency command source during communication operation
NOTE
• The PU operation mode has a higher priority when
Pr.550
= "2" (NET mode using the PU connector) and
Pr.551
= "2" (PU
mode using the PU connector). For this reason, if the communication option is not mounted, switching to the Network operation
mode is no longer possible.
• Changed setting values are enabled at power-ON or inverter reset.
• Standard model
• Ethernet model / Safety communication model
PU: Enabled in PU operation mode, NET: Enabled in Network operation mode, ×: Not available
*1
When the enclosure surface operation panel (FR-PA07) is used.
*2
The MODBUS RTU protocol cannot be used in the PU operation mode.
Pr.550
setting
Pr.551
setting
Command source
Remarks
Operation
panel
USB
connector
PU connector
Communication
option
Operation
option
RS-485
communication
0
2
×
×
PU
NET
3
×
PU
×
×
NET
4
PU
×
×
×
NET
9999 (initial
value)
PU
×
NET
2
2
×
×
PU
×
Switching to NET
operation mode disabled
3
×
PU
×
NET
×
4
PU
×
×
NET
×
9999 (initial
value)
PU
NET
×
9999
(initial
value)
2
×
×
PU
NET
3
×
PU
×
×
NET
With communication
option
NET
×
Without communication
option
4
PU
×
×
×
NET
With communication
option
NET
×
Without communication
option
9999 (initial
value)
PU
×
NET
With communication
option
NET
×
Without communication
option
Pr.550
setting
Pr.551
setting
Command source
Remarks
Operation panel
USB connector
Ethernet
connector
Communication
option
0
3
×
PU
×
NET
4
PU
×
×
NET
9999 (initial
value)
×
NET
5
3
×
PU
NET
×
4
PU
×
NET
×
9999 (initial
value)
NET
×
9999
(initial
value)
3
×
PU
×
NET
With communication option
NET
×
Without communication
option
4
PU
×
×
NET
With communication option
NET
×
Without communication
option
9999 (initial
value)
×
NET
With communication option
NET
×
Without communication
option
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...