12. (M) Item and Output Signal for Monitoring
12.5 Energy saving monitoring
• The items in the cumulative energy saving monitoring (items which can be monitored when "51" is set in
Pr.52, Pr.774 to
Pr.776
, and
Pr.992
) are listed below.
(The digit of the cumulative energy saving monitored value can be moved to the right according to the setting of
Pr.891
Cumulative power monitor digit shifted times
.)
*1
For monitoring via communication, the increments are 1 in no units. For example, a value "10.00 kWh" is converted into "10" for communication
data.
*2
On the LCD operation panel, a readout is displayed in units of kilowatt-hours (kW).
NOTE
• The operation panel have a 4-digit display. This means, for example, that a monitored value up to "99.99" is displayed in 0.01
increments and a monitor value of 1000 or more is displayed in 0.1 increments as "100.0". The maximum monitored value
displayed is "9999".
• The maximum monitored value via communication is 65535 when
Pr.898 Power saving cumulative monitor clear
= "9999".
The maximum monitored value on monitoring in 0.01 increments is "655.35", and that on monitoring in 0.1 increments is
"6553.5".
Power saving real-time monitoring ([1 Power saving], [2 Power saving
rate])
• During
[1 Power saving]
monitoring, an energy saving effect (power difference) of using the inverter as compared to the
commercial power supply operation is calculated and displayed on the main monitor.
• In the following cases, the monitored value of
[1 Power saving]
is "0".
• On
[2 Power saving rate]
monitoring, the rate of the saved power considering the consumed power (estimate) during the
power supply operation as 100% is displayed when
Pr.895 Power saving rate reference value
is set to "0". When
Pr.895
is set to "1", the rate of the saved power with respect to the setting of
Pr.893 Energy saving monitor reference (motor
capacity)
that is referenced as 100% is displayed.
Average power saving monitoring ([3 Average power saving], [4 Average
power saving rate], [5 Average power cost savings])
• The average power saving monitors are displayed by setting a value other than 9999 in
Pr.897 Power saving monitor
average time
.
• On
[3 Average power saving]
monitoring, the average hourly energy saving every preset time period is displayed.
Energy saving
monitor item
Description and formula
Unit and
increment
Parameter setting
Pr.895
Pr.896
Pr.897
Pr.899
6
Power saving
amount
It is defined as a cumulative energy saving during
monitoring, determined by multiplying the saved
power by the number of inverter operating hours.
Σ
(
[1 Power saving]
×
Δ
t)
0.01
kWh
—
9999
—
9999
7
Power cost savings
It is defined as a monetary value of the cumulative
energy saving.
[6 Power saving amount] × Pr.896 setting
—
0 to 500
8
Annual power saving
amount
It is defined as an estimated annual energy saving.
0.01
kWh
—
9999
0% to
100%
9
Annual power cost
savings
It is defined as a monetary value of annual energy
saving.
[8 Annual power saving amount] × Pr.896 setting
—
0 to 500
[6 Power saving amount]
Operation time during power
saving accumulation
× 24 × 365 ×
Pr.899
100
The result of calculating the saved power is negative value.
DC injection brake works.
The motor is not connected with the inverter (monitored value of output
current is 0 A).
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...