18. Appendix
18.4 Parameters (functions) and instruction codes under different control methods
18.4
Parameters (functions) and instruction codes
under different control methods
*1
Instruction codes are used to read and write parameters in accordance with communication (such as the Mitsubishi inverter protocol). (For details
of communication, refer to the Instruction Manual (Communication).)
*2
Function availability under each control method is shown as follows:
○
: Available
×: Not available
Δ
: Available with some restrictions
*3
For Parameter copy, Parameter clear, and All parameter clear,
○
indicates the function is available, and × indicates the function is not available.
*4
Communication parameters that are not cleared by parameter clear or all parameter clear (H5A5A or H55AA) via communication. (For details of
communication, refer to the Instruction Manual (Communication).)
*5
When a communication option is installed, parameter clear (lock release) during password lock (
Pr.297 Password lock/unlock
≠
”9999”) can be
performed only from the communication option.
Notation
Mark
Description
Mark
Description
Available for the standard model.
Available for the 400 V class inverters.
Available for the FM type inverter (standard model).
Available for the three-phase power input model.
Available for the AM (50 Hz) type inverter (standard model).
Available when the FR-A8AP is installed.
Available for the AM (60 Hz) type inverter (standard model).
Available when the FR-A8AX is installed.
Available for the Ethernet model and the safety
communication model.
Available when the FR-A8AY is installed.
Available for the Protocol group A (Ethernet model / safety
communication model).
Available when the FR-A8AR is installed.
Available when the FR-A8NC is installed.
Available for the safety communication model.
Available when the FR-A8ND is installed.
Available for the 200 V class inverters.
Available when the FR-A8NP is installed.
Pr.
Name
Instruction
code
Control method
Parameter
Read
Writ
e
Ex
te
nd
ed
Cop
y
C
lear
All clea
Sp
eed
To
rqu
e
Sp
eed
To
rqu
e
Sp
eed
0
Torque boost
00
80
0
○
×
×
×
×
×
×
○
○
○
1
Maximum frequency
01
81
0
○
○
○
○
○
○
○
○
○
○
2
Minimum frequency
02
82
0
○
○
○
○
○
○
○
○
○
○
3
Base frequency
03
83
0
○
×
×
×
×
×
×
○
○
○
4
Multi-speed setting (high speed)
04
84
0
○
○
○
○
○
○
○
○
○
○
5
Multi-speed setting (middle speed)
05
85
0
○
○
○
○
○
○
○
○
○
○
6
Multi-speed setting (low speed)
06
86
0
○
○
○
○
○
○
○
○
○
○
7
Acceleration time
07
87
0
○
○
○
○
○
○
○
○
○
○
8
Deceleration time
08
88
0
○
○
○
○
○
○
○
○
○
○
9
Electronic thermal O/L relay
09
89
0
○
○
○
○
○
○
○
○
○
○
10
DC injection brake operation frequency 0A
8A
0
○
○
○
○
○
○
○
○
○
○
11
DC injection brake operation time
0B
8B
0
○
○
○
○
○
○
○
○
○
○
12
DC injection brake operation voltage
0C
8C
0
○
○
×
×
×
×
×
○
○
○
13
Starting frequency
0D
8D
0
○
○
○
○
○
○
○
○
○
○
14
Load pattern selection
0E
8E
0
○
×
×
×
×
×
×
○
○
○
15
Jog frequency
0F
8F
0
○
○
○
○
○
○
○
○
○
○
16
Jog acceleration/deceleration time
10
90
0
○
○
○
○
○
○
○
○
○
○
17
MRS/X10 terminal input selection
11
91
0
○
○
○
○
○
○
○
○
○
○
18
High speed maximum frequency
12
92
0
○
○
○
○
○
○
○
○
○
○
19
Base frequency voltage
13
93
0
○
×
×
×
×
×
×
○
○
○
20
Acceleration/deceleration reference
frequency
14
94
0
○
○
○
○
○
○
○
○
○
○
21
Acceleration/deceleration time
increments
15
95
0
○
○
○
○
○
○
○
○
○
○
V/FV/FV/F
Magnetic fluxMagnetic fluxMagnetic flux
Vector
Vector
Vector
Sensorless
Sensorless
Sensorless
PM
PM
PM
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...