340
14. (C) Motor Constant Parameters
14.1 Applied motor
14
(C) Motor Constant Parameters
14.1
Applied motor
By setting the applied motor type, the thermal characteristic appropriate for the motor can be selected.
When using a constant-torque or PM motor, the electronic thermal O/L relay function is set according to the motor.
When the Advanced magnetic flux vector control, Real sensorless vector control, Vector control, or PM sensorless vector
control is selected, the motor constant necessary for control (for SF-PR, SF-PR-SC, SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-
V5RU (1500 r/min series), GM-[], GM-DZ, or GM-DP) is also selected at the same time.
*1
The setting range for the 575 V class is "0, 3, 5, 6, 10, 13, 15, 16, 30, 33, 8090, 8093, 9090, and 9093".
Purpose
Parameter to set
Refer to page
To select the motor to be used
Applied motor
P.C100, P.C200
Pr.71, Pr.450
To maximize the performance of the
induction motor
Offline auto tuning
P.C100 to P.C105,
P.C107, P.C108,
P.C110, P.C120 to
P.C126, P.C182,
PC188, P.C200 to
P.C205, P.C207,
P.C208, P.C210,
P.C220 to P.C226,
P.C282, P.C288
Pr.9, Pr.51, Pr.71,
Pr.80 to Pr.84, Pr.90 to
Pr.94, Pr.96, Pr.450,
Pr.453 to Pr.463,
Pr.707, Pr.717, Pr.720,
Pr.724, Pr.737, Pr.741,
Pr.744, Pr.745, Pr.859,
Pr.860
To maximize the performance of the
PM motor
PM motor offline auto
tuning
P.C100 to P.C108,
P.C110, P.C120,
P.C122, P.C123,
P.C126, P.C130 to
P.C133, P.C135,
P.C150, P.C182,
P.C185, P.C200 to
P.C208, P.C210,
P.C220, P.C222,
P.C223, P.C226,
P.C230 to P.C233,
P.C235, P.C282,
P.C285
Pr.9, Pr.51, Pr.71,
Pr.80, Pr.81, Pr.83,
Pr.84, Pr.90, Pr.92,
Pr.93, Pr.96, Pr.450,
Pr.453, Pr.454, Pr.456
to Pr.458, Pr.460,
Pr.461, Pr.463, Pr.702,
Pr.706, Pr.707, Pr.711,
Pr.712, Pr.717, Pr.721,
Pr.724, Pr.725, Pr.738
to Pr.746, Pr.859,
Pr.860, Pr.1002,
Pr.1412, Pr.1413
To perform high accuracy operation
without being affected by temperature
and high-torque/ultra-low speed
Online auto tuning
P.C111, P.C211
Pr.95, Pr.574
To use the motor with encoder
Encoder
specifications
P.C140, P.C141
Pr.359, Pr.369
To detect loss of encoder signals
Signal loss detection
P.C148
Pr.376
Pr.
Name
Initial value
Setting range
Description
71
C100
Applied motor
0
0, 3, 5, 6, 10, 13, 15, 16, 20, 23,
30, 33, 40, 43, 50, 53, 70, 73,
1800, 1803, 8090, 8093, 9090,
9093
By selecting a motor, the thermal characteristic
and motor constant of each motor are set.
450
C200
Second applied motor
9999
0, 3, 5, 6, 10, 13, 15, 16, 20, 23,
30, 33, 40, 43, 50, 53, 70, 73,
1800, 1803, 8090, 8093, 9090,
9093
Set this parameter when using the second motor
(the same specifications as
Pr.71
).
9999
The function is disabled.
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...