212
10. (D) Operation Command and Frequency Command
10.1 Operation mode selection
10
(D) Operation Command and Frequency
Command
10.1
Operation mode selection
Select the operation mode of the inverter.
The mode can be changed among operation using external signals (External operation), operation by the operation panel (PU
operation), combined operation of PU operation and External operation (External/PU combined operation), and Network
operation (via RS-485 communication or Ethernet communication, or when a communication option is used).
The following table lists valid and invalid commands in each operation mode.
Purpose
Parameter to set
Refer to
page
To select the operation mode
Operation mode selection P.D000
Pr.79
To start up the inverter in Network operation
mode at power-ON
Communication startup
mode selection
P.D000, P.D001
Pr.79, Pr.340
To select the command source during
communication operation
Operation and speed
command sources during
communication operation,
command source
selection
P.D010 to P.D013
Pr.338, Pr.339, Pr.550,
Pr.551
To prevent the motor from rotating
reversely
Reverse rotation
prevention selection
P.D020
Pr.78
To change the setting resolution of the
torque limit
Set resolution switchover P.D030
Pr.811
To perform JOG (inching) operation
JOG operation
P.D200, P.F002
Pr.15, Pr.16
To control the frequency with combinations
of terminals
Multi-speed operation
P.D301 to P.D315
Pr.4 to Pr.6, Pr.24 to
Pr.27, Pr.232 to Pr.239
To select the torque command method
during torque control
Torque command source
selection
P.D400 to P.D402
Pr.804 to Pr.806
Pr.
Name
Initial value
Setting range
Description
79
D000
Operation mode selection
0
0 to 4, 6, 7
Selects the operation mode.
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...