6. Torque Control
6.4 Torque command
1
2
3
4
5
6
7
8
9
10
6.4
Torque command
For torque control selection, the torque command source can be selected.
*1
Torque commands can be input via CC-Link, CC-Link IE TSN, CC-Link IE Field Network Basic, and PROFIBUS-DP communication. CC-Link and
PROFIBUS-DP communication are unavailable when the Vector control compatible options is installed.
Control block diagram
NOTE
• When the torque command exceeding the torque limit value (
Pr.22, Pr.810, Pr.812 to Pr.817
) is given, the output torque is
within the torque limit value. (Refer to
.)
Torque command given by analog input (terminal 4) (Pr.804 = "0" (initial
value))
• Torque commands are given by voltage (current) input via terminal 4.
• Set
Pr.858 Terminal 4 function assignment
= "4" to give the torque command via terminal 4.
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
Pr.
Name
Initial
value
Setting range
Description
801
H704
Output limit level
9999
0% to 400%
Set the torque current limit level.
9999
The torque limit setting value is used for limiting the torque current level.
803
G210
Constant output range
torque characteristic
selection
0
0, 10
Constant motor output command
In the torque command setting,
select torque command for the
constant output area.
1
Constant torque command
2
The torque is constant unless the
output limit of the torque current is
reached. (The torque current is
limited.)
804
D400
Torque command
source selection
0
0
Torque command given by analog input via terminal 4
1
Torque command (-400% to 400%) given by the parameter setting
(
Pr.805
or
Pr.806
)
3
Torque command via communication
4
12/16-bit digital input (FR-A8AX)
5
Torque command via communication
6
805
D401
Torque command value
(RAM)
1000%
600% to
1400%
Writes the torque command value in RAM. Regards 1000% as 0%, and
set torque command by an offset of 1000%.
806
D402
Torque command value
(RAM, EEPROM)
1000%
600% to
1400%
Writes the torque command value in RAM and EEPROM Regards
1000% as 0%, and set torque command by an offset of 1000%.
+
-
-
Parameter [
Pr. 805, Pr. 806
]
16-bit digital input
(FR-A8AX)
Speed limit input
Speed control
Analog input
0
1,3,5,6
4
[
Pr. 804
]
Torque command
source selection
Torque control
+
Motor
Speed
estimated
value
Real sensorless vector control
Speed
estimated
value
Speed estimator
<Speed limit value
Speed limit value
Vector control
Encoder
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...