(E) Environment setting parameters
258
GOT initial setting (RS-485 terminals) (Pr.999 = "11, 13")
When
Pr.414
="1", the setting value is not changed.
• Initial setting with the GOT2000 series
- When "FREQROL 500/700/800, SENSORLESS SERVO" is selected for "Controller Type" in the GOT setting, set
Pr.999
="11" to configure the GOT initial setting.
- When "FREQROL 800(Automatic Negotiation)" is selected for "Controller Type" in the GOT setting, the GOT automatic
connection can be used. When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT setting
and the GOT automatic connection is not used, set
Pr.999
="13" to configure the GOT initial setting. (Refer to
)
• Initial setting with the GOT1000 series
- Set
Pr.999
="11" to configure the GOT initial setting.
NOTE
• Always perform an inverter reset after the initial setting.
• For the details of connection with GOT, refer to the Instruction Manual of GOT.
Rated frequency (Pr.999 = "20 (50 Hz), 21 (60 Hz)")
Pr.
Name
Initial
value
Pr.999="11"
Pr.999="13"
Refer to
page
79
Operation mode selection
0
0
0
332
RS-485 communication speed
96
192
1152
333
RS-485 communication stop bit length
1
10
0
334
RS-485 communication parity check selection
2
1
1
335
RS-485 communication retry count
1
9999
9999
336
RS-485 communication check time interval
0 s
9999
9999
337
RS-485 communication waiting time setting
9999
0 ms
0 ms
340
Communication startup mode selection
0
1
1
341
RS-485 communication CR/LF selection
1
1
1
414
PLC function operation selection
0
—
2
549
Protocol selection
0
0
0
Pr.
Name
Initial
value
Pr.999 = "21" Pr.999 = "20"
Refer to
page
3
Base frequency
60 Hz
60 Hz
50 Hz
4
Multi-speed setting (high speed)
60 Hz
60 Hz
50 Hz
20
Acceleration/deceleration reference frequency
60 Hz
60 Hz
50 Hz
37
Speed display
0
0
55
Frequency monitoring reference
60 Hz
60 Hz
50 Hz
66
Stall prevention operation reduction starting
frequency
60 Hz
60 Hz
50 Hz
116
Third output frequency detection
60 Hz
60 Hz
50 Hz
125 (903)
Terminal 2 frequency setting gain frequency
60 Hz
60 Hz
50 Hz
126 (905)
Terminal 4 frequency setting gain frequency
60 Hz
60 Hz
50 Hz
263
Subtraction starting frequency
60 Hz
60 Hz
50 Hz
266
Power failure deceleration time switchover
frequency
60 Hz
60 Hz
50 Hz
386
Frequency for maximum input pulse
60 Hz
60 Hz
50 Hz
505
Speed setting reference
60 Hz
60 Hz
50 Hz
808
Forward rotation speed limit/speed limit
60 Hz
60 Hz
50 Hz
918
Terminal 1 gain frequency (speed)
60 Hz
60 Hz
50 Hz